Appendix G

H:Health Industry Bar Code (HIBC; Code 39 bar code with a modulo 43 checksum)

Valid Characters: 0 – 9, A – Z, -, $, /, ., %, +

Variable Length.

Valid bar dimensions: The expected ratio of wide to narrow bars can range from 2:1 to 3:1. The host must supply the leading plus character (+).

The following example prints a HIBC bar code with a wide to narrow bar ratio of 3:1:

<STX>L

D11

1H0000000150050+0123456789<CR> 121100000000100Barcode H<CR>

E

I:Codabar

Valid Characters: 0 – 9, A – D - . $ : / +

Variable Length (requiring at least three characters).

Valid bar dimensions: The expected ratio of wide to narrow bars can range from 2:1 to 3:1. Valid symbols require start and stop characters (A – D) . These characters should be placed in the data field along with the data to be included in the symbol.

The following example prints a Codabar bar code with a wide to narrow bar ratio of 3:1:

<STX>L

D11

1I63040001501000A1234567890D<CR>

121100000000100Barcode I<CR>Barcode I E

J:Interleaved 2 of 5 with a modulo 10 checksum. Valid Characters: 0 – 9

Variable Length.

Valid bar dimensions: The expected ratio of wide to narrow bars can range from 2:1 to 3:1.

The following example prints an I2 of 5 bar code with a modulo 10 checksum added and a wide to narrow bar ratio of 3:1:

<STX>L

D11

1J000000015010001234567890<CR> 121100000000100Barcode J<CR>

E

E-Class DPL Programmer’s Manual