System-Level Commands

STX w Test Flash Memory Module

This command tests the Flash memory module. The time for each test will vary from 20 to 120 seconds, depending upon the size of the module. (When testing the optional module, jumpers must be installed.) All stored data will be destroyed. If no module is present, there will be no printer response.

Syntax:

<STX>wa

 

Where:

a

-

Module designator; see Appendix J.

Printer response format:

Module A: xxxxK results

Where:

A

-

Module tested.

 

xxxx

-

Module size in kilobytes.

 

results

-

Test results given as ‘Good’ or ‘Bad’.

STX X Set Default Module

This command, typically used prior to the loading of PCL-4 bit-mapped fonts (see Font-Loading Commands), is designed to allow the user to select between modules when downloading information. The default module is one of the following:

1.The first alpha designator of the existing modules if item 2 has not occurred.

2.The module selected by this command.

Syntax:<STX>Xa

Where:

a

- Module designator, A or B; see Appendix J.

Sample:<STX>XB

The sample sets ‘B’ as the default module.

24

E-Class DPL Programmer’s Manual

Page 34
Image 34
Datamax E4203 manual STX w Test Flash Memory Module, STX X Set Default Module, STXw a