Label-Formatting Commands

^

Set Count by Amount

This command allows applications using the increment / decrement field command to print more than one label with the same field value before the field data is updated. All printers default to 1.

Note: This command can only be issued once per label format. In addition, when alternate Control Codes are enabled, the ^ character must be replaced by the @ character (hexadecimal 0x40). See Control Codes.

Syntax:

Where:

Sample:

^nn

^- May be 0x55 or 0x40, see Control Codes.

nn- Is a two-digit value that specifies the number of labels to be generated before incrementing (or decrementing) the field value.

<STX>L<CR>

13220000000000012345<CR> -01<CR>

^02<CR>

Q0006<CR>

E<CR>

The sample prints two labels containing the same field value before decrementing the field. Six labels are printed.

Special Label-Formatting Commands

Two Special Label-Formatting Commands, the <STX> S and the <STX> T, are entered directly into the data field of label format records. Do not confuse them with System-Level Commands because the same control character is used. If alternate control codes are enabled the <STX> becomes ‘~’ (hexadecimal 0x7E); see Control Codes.

Label-Formatting Character

Command Description

<STX>S

Recall global data and place in field

<STX>T

Print time and date

Table 6-2: Special Label-Formatting Commands

54

E-Class DPL Programmer’s Manual

Page 64
Image 64
Datamax E4203 manual Special Label-Formatting Commands, Set Count by Amount