Bard 357-93-E Back View, Side View, Front View, Models, Left Side, Right Side, Supply Air Duct

Models: 357-93-E

1 12
Download 12 pages 51.81 Kb
Page 11
Image 11
MODELS

Clearances Required for Service Access and Adequate Condenser Air Flow

MODELS

LEFT SIDE

RIGHT SIDE

WL18, WL24, WL25, WL37

20"

15"

 

 

 

WL42, WL48, WL60, WL70

20"

20"

 

 

 

NOTE: For side by side installation of two (2) WL models there must be 20" between units. This can be reduced to 15" by using a WL model (left side compressor and controls) for the left unit and WA (right side compressor and controls) for right unit.

Minimum Clearances Required to Combustible Materials

MODELS 1

SUPPLY AIR DUCT

 

FIRST THREE FEET

CABINET

 

WL18, WL24, WL25

0"

0"

 

 

 

WL30, WL37

1/4"

0"

 

 

 

WL42, WL48, WL60, WL70

1/4"

0"

 

 

 

1 Refer to the Installation Manual for more detailed information.

Dimensions of Basic Unit for Architectural and Installation Requirements (Nominal)

MODEL

WIDTH

DEPTH

HEIGHT

SUPPLY

RETURN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(W)

(D)

(H)

A

B

C

B

E

F

G

I

J

K

L

M

N

O

P

Q

R

S

T

WL18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WL24

33.300

17.125

70.563

7.88

19.88

11.88

19.88

35.00

18.50

25.75

20.56

26.75

28.06

29.25

27.00

2.63

34.13

22.06

10.55

4.19

12.00

5.00

WL25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WL30

38.200

17.125

70.563

7.88

27.88

13.88

27.88

40.00

18.50

25.75

17.93

26.75

28.75

29.25

27.00

2.75

39.19

22.75

9.14

4.19

12.00

5.00

WL37

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WL42

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WL48

42.075

22.432

84.875

9.88

29.88

15.88

29.88

43.88

19.10

31.66

30.00

32.68

26.94

34.69

32.43

3.37

42.88

23.88

10.00

2.00

16.00

1.88

WL60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WL70

42.075

22.432

94.875

9.88

29.88

15.88

29.88

43.88

19.10

41.66

30.00

42.68

36.94

44.69

42.43

3.37

42.88

33.88

10.00

2.00

16.00

1.88

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All dimensions are in inches. Dimensional drawings are not to scale.

1

1

BACK VIEW

SIDE VIEW

FRONT VIEW

1 21.00 inches on model WL701

Form No.

S3279-206

Supersedes

S3279-106

Page