Air Conditioning Wall-Mount Model Nomenclature
WL 37 2
MODEL NUMBER REVISION
A 10 | X | X | X | X |
KW
XJ
CONTROL MODULES
J - Standard on all models
CAPACITY
18 - 1½ Ton
24 - 2 Ton
25 - 2 Ton
30 - 2½ Ton
37 - 3 Ton
42 - 3½ Ton
48 - 4 Ton
60 - 5 Ton
VOLTS & PHASE A - 230/208/60/1 B - 230/208/60/3
VENTILATION OPTIONS
See Table Below
COLOR OPTIONS
X - Beige (Standard)
1 - White
2 - Mesa Tan
4 - Buckeye Gray
5 - Desert Brown
8 - Dark Bronze
COIL OPTIONS X - Standard
1 - Phenolic Coated Evaporator
2 - Phenolic Coated Condenser
3 - Phenolic Coated Evaporator and Condenser
70 - 6 Ton
C - 460/60/3
FILTER OPTIONS
X- 1 inch Disposable (Standard) W - 1 inch Washable
P - 2 inch Pleated
OUTLET OPTIONS X - Front (Standard)
NOTE: For 0 KW and circuit breakers (230/208 Volt) or toggle disconnects (460 Volt) applications, insert 0Z in the KW field of the model number.
Ventilation Options
Models | WL18, WL24, WL25 | WL30, WL37 | WL42, WL48, WL60, WL70 | ||||
Description | Factory Installed | Field Installed | Factory Installed | Field Installed | Factory Installed | Field Installed | |
Code No. | Part No. | Code No. | Part No. | Code No. | Part No. | ||
| |||||||
Barometric Fresh Air | X | X | X | ||||
|
|
|
|
|
|
| |
B | B | B | |||||
|
|
|
|
|
|
| |
Motorized Fresh Air Damper | M | M | M | ||||
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
Commercial Ventilator - Spring Return w/Exhaust | V | V | V | ||||
|
|
|
|
|
|
| |
Commercial Ventilator - Power Return w/Exhaust | P | P | |||||
Economizer - Fully Modulating 1 | E | E | E | ||||
|
|
|
|
|
|
| |
Economizer - Fully Modulating 12 | D | N/A | D | N/A | D | N/A | |
|
|
|
|
|
|
|
1 Low ambient control is required with economizer for low temperature compressor operation. 2 For use only with “V” Control Module and TCS22 Controller.
Air Conditioning Control Modules |
|
|
| All |
| |||
|
|
|
|
|
|
| Models | |
|
| AVAILABLE CONTROL OPTIONS |
|
| ||||
|
|
|
|
|
| |||
HPC 1 | LPC 2 | CCM 3 | LAC 4 | ALR 5 | SK 6 | DDC 7 | Factory Installed Code | Field Installed Part |
Standard | Standard | Standard | Standard | Standard |
|
| J | Factory Only |
|
|
|
|
|
|
|
|
|
Standard | Standard | Standard | Standard | Standard |
| M6 | Factory Only | |
|
|
|
|
|
|
|
|
|
Standard | Standard | Standard | Standard | Standard |
| V8 | Factory Only | |
|
|
|
|
|
|
|
|
|
1 HPC: High pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3.
2 LPC: Low pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3.
3CCM: Compressor control module has adjustable
4 LAC: Low ambient control permits cooling operation down to 0°F.
5 ALR: The alarm relay has a set of normally open and normally closed dry contacts to provide the ability to signal a condition of shutdown on either high or low pressure controls.
6 SK: Start kit can be used with all
7 DDC: Incorporates 4 additional sensors: discharge air temperature, indoor blower airflow, compressor current, and dirty filter. These sensing devices function to input analog data such as temperature, as well as digital data such as air flow, compressor status or filter status.
8 "V" control module should be ordered in conjunction with direct digital controller (DDC) model TCS22. Refer to DDC specification sheet S3280 for more information.
BARD MANUFACTURING CO. | Due to our continuous product improvement |
BRYAN, OHIO 43506 | policy, all specifications subject to change |
www.bardhvac.com | without notice. |
| Before purchasing this appliance, read important energy |
| cost and efficiency information available from your retailer. |
Form No.
S3279
February, 2006
Supersedes
Form No. | |
Supersedes | |
Page | 12 of 12 |