Air Conditioning Wall-Mount Model Nomenclature

Air Conditioning Wall-Mount Model Nomenclature

WL 37 2

MODEL NUMBER WL 37 2Models REVISION

A 10

X

X

X

X

KW

XJ

CONTROL MODULES

J - Standard on all models

CAPACITY

18 - 1½ Ton

24 - 2 Ton

25 - 2 Ton

30 - 2½ Ton

37 - 3 Ton

42 - 3½ Ton

48 - 4 Ton

60 - 5 Ton

VOLTS & PHASE A - 230/208/60/1 B - 230/208/60/3

VENTILATION OPTIONS

See Table Below

COLOR OPTIONS

X - Beige (Standard)

1 - White

2 - Mesa Tan

4 - Buckeye Gray

5 - Desert Brown

8 - Dark Bronze

COIL OPTIONS X - Standard

1 - Phenolic Coated Evaporator

2 - Phenolic Coated Condenser

3 - Phenolic Coated Evaporator and Condenser

70 - 6 Ton

C - 460/60/3

FILTER OPTIONS

X- 1 inch Disposable (Standard) W - 1 inch Washable

P - 2 inch Pleated

OUTLET OPTIONS X - Front (Standard)

NOTE: For 0 KW and circuit breakers (230/208 Volt) or toggle disconnects (460 Volt) applications, insert 0Z in the KW field of the model number.

Ventilation Options

Models

WL18, WL24, WL25

WL30, WL37

WL42, WL48, WL60, WL70

Description

Factory Installed

Field Installed

Factory Installed

Field Installed

Factory Installed

Field Installed

Code No.

Part No.

Code No.

Part No.

Code No.

Part No.

 

Barometric Fresh Air Damper-Standard

X

BFAD-2

X

BFAD-3

X

BFAD-5

 

 

 

 

 

 

 

Blank-Off Plate

B

BOP-2

B

BOP-3

B

BOP-5

 

 

 

 

 

 

 

Motorized Fresh Air Damper

M

MFAD-2

M

MFAD-3

M

MFAD-5

 

 

 

 

 

 

 

 

 

 

 

 

 

Commercial Ventilator - Spring Return w/Exhaust

V

CRV-2

V

CRVS-3

V

CRVS-5

 

 

 

 

 

 

 

Commercial Ventilator - Power Return w/Exhaust

---

---

P

CRVP-3

P

CRVP-5

Economizer - Fully Modulating 1

E

EIFM-2B

E

EIFM-3C

E

EIFM-5C

 

 

 

 

 

 

 

Economizer - Fully Modulating 12

D

N/A

D

N/A

D

N/A

 

 

 

 

 

 

 

1 Low ambient control is required with economizer for low temperature compressor operation. 2 For use only with “V” Control Module and TCS22 Controller.

Air Conditioning Control Modules

 

 

 

All

 

 

 

 

 

 

 

 

Models

 

 

AVAILABLE CONTROL OPTIONS

 

 

 

 

 

 

 

 

HPC 1

LPC 2

CCM 3

LAC 4

ALR 5

SK 6

DDC 7

Factory Installed Code

Field Installed Part

Standard

Standard

Standard

Standard

Standard

 

 

J

Factory Only

 

 

 

 

 

 

 

 

 

Standard

Standard

Standard

Standard

Standard

￿

 

M6

Factory Only

 

 

 

 

 

 

 

 

 

Standard

Standard

Standard

Standard

Standard

 

￿

V8

Factory Only

 

 

 

 

 

 

 

 

 

1 HPC: High pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3.

2 LPC: Low pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3.

3CCM: Compressor control module has adjustable 30-second to 5-minute delay-on-break timer (which also provides a delay-on-make equal to 10% of delay- on-break setting). The module also provides the lockout feature (with 1 retry) for high and/or low pressure controls, and a 2-minute timed bypass for low pressure control.

4 LAC: Low ambient control permits cooling operation down to 0°F.

5 ALR: The alarm relay has a set of normally open and normally closed dry contacts to provide the ability to signal a condition of shutdown on either high or low pressure controls.

6 SK: Start kit can be used with all -A single phase models only. Is not used or available for -B or -C three phase models.

7 DDC: Incorporates 4 additional sensors: discharge air temperature, indoor blower airflow, compressor current, and dirty filter. These sensing devices function to input analog data such as temperature, as well as digital data such as air flow, compressor status or filter status.

8 "V" control module should be ordered in conjunction with direct digital controller (DDC) model TCS22. Refer to DDC specification sheet S3280 for more information.

BARD MANUFACTURING CO.

Due to our continuous product improvement

BRYAN, OHIO 43506

policy, all specifications subject to change

www.bardhvac.com

without notice.

 

Before purchasing this appliance, read important energy

 

cost and efficiency information available from your retailer.

Form No.

S3279

February, 2006

Supersedes S3279-106

Form No.

S3279-206

Supersedes

S3279-106