Air Conditioning Wall-Mount Model Nomenclature

W 36 A 1

A

10 X

X X

X

X

X

SERIES

NOMINAL

CAPACITY

17 - 1½ Ton

18 - 1½ Ton

24 - 2 Ton

30 - 2½ Ton

36 - 3 Ton

42 - 3½ Ton

48 - 4 Ton

60 - 5 Ton

REVISION

TYPE

Air Conditioner

Specialty Products 2

(Non-Standard)

VOLTS & PHASE

A - 230/208/60/1

B - 230/208/60/3

C - 460/60/3

KW 1

VENTILATION OPTIONS

(See Table Below)

FILTER OPTIONS

X- 1-inch Throwaway (Standard) W - 1-inch Washable

P - 2-inch Pleated (MERV 8)

COLOR OPTIONS

X - Beige (Standard)

1 - White

4 - Buckeye Gray

5 - Desert Brown

8 - Dark Bronze

A - Aluminum

S - Stainless Steel

CONTROL MODULES

(See Chart Below)

COIL OPTIONS

X - Standard

1 - Phenolic Coated Evaporator

2 - Phenolic Coated Condenser

3 - Phenolic Coated Evaporator

and Condenser

OUTLET OPTIONS

X - Front (Standard)

T - Top (on W30A and

W36A Models)

1For 0KW and circuit breakers (230/208 Volt) or toggle disconnects (460 Volt) applications, insert 0Z in the KW field of the model number. See Page 8 for available Factory Installed KW options and Page 9 for Field Installed Heater Packages.

2Insert “D” for dehumidification with hot gas reheat — Models W42 - 60 only. See Form 7960-572 for complete details.

Ventilation Options

Models

W17A1, W18A1, W24A1

 

W30A1, W36A1

W42A1, W48A1, W60A1

Description

Factory Installed

Field Installed

Factory Installed

Field Installed

Factory Installed

Field Installed

Code No.

Part No.

 

Code No.

Part No.

Code No.

Part No.

 

 

Barometric Fresh Air Damper - Standard

X

BFAD-2

 

X

BFAD-3

X

BFAD-5

Blank-Off Plate

B

BOP-2

 

B

BOP-3

B

BOP-5

Motorized Fresh Air Damper

M

MFAD-2

 

M

MFAD-3

M

MFAD-5

Commercial Ventilator - Spring Return w/Exhaust

V

CRV-2

 

V

CRVS-3

V

CRVS-5

Commercial Ventilator - Power Return w/Exhaust

---

---

 

P

CRVP-3

P

CRVP-5

Economizer - School Versions, Enthalpy 4

S

ECONWMS-E2 23

S

ECONWMS-E3 23

S

ECONWMS-E5 23

Economizer - Equipment Bldg., Enthalpy 5

W

ECONWMT-E2 2

W

ECONWMT-E3 2

W

ECONWMT-E5 2

Economizer - Equipment Bldg., DB Temp 5

T

ECONWMT-T2 2

T

ECONWMT-T3 2

T

ECONWMT-T5 2

Energy Recovery Ventilator - 230 Volt 3

R

ERVF-A2

R

ERVF-A3 1

R

ERVF-A5 1

Energy Recovery Ventilator - 460 Volt 3

N/A

ERVF-C2

6

R

ERVF-C3 1

R

ERVF-C5 1

Door Kit for ERVF (Required)

N/A

WMDK2-

3

N/A

WMDK3- 3

N/A

WMDK5- 3

1Intake and exhaust can be independently adjusted.

2Insert color to match unit ("X" = Beige; "4" = Buckeye Gray; etc.)

3WMDK Door Kit must be ordered in addition to ERVF Assembly and ECONWMS & color matched to unit ("X" = Beige; "4" = Buckeye Gray; etc.)

4 Partial Full Flow (75% of Rated Cooling CFM). All ECONWMS versions have 3" deep intake hood.

5 Full Flow (100% of Rated Cooling CFM). ECONWMT 2 and 3 have 16" deep intake hood; ECONWMT- 5 has 18" deep intake hood.

6Model W24A1-C only.

Air Conditioning Control Modules

 

 

 

All Models Except As Noted

W17A1

 

 

 

 

 

 

 

 

 

 

 

 

Factory

HPC 1

LPC 2

CCM 3

LAC 411

ALR 5

SK 6

SK 7

ODT 8

DDC 9

Factory Installed Code

Field Installed Part

Only

 

 

 

 

 

 

 

 

 

 

 

 

 

STD

STD

STD

 

 

 

 

 

 

X

 

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

STD

STD

STD

z

 

 

 

 

 

E

11

CMA-28

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

STD

STD

STD

z

z

 

 

 

 

J

11

Factory Only

J

 

 

 

 

 

 

 

 

 

 

 

 

 

STD

STD

STD

z

 

z

 

 

 

K

11

CMC-15 and CMA-28

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

STD

STD

STD

z

z

z

 

 

 

M

11

Factory Only

M

 

 

 

 

 

 

 

 

 

 

 

 

STD

STD

STD

 

z

 

 

 

 

N, W18A Only 12

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

 

STD

STD

STD

 

 

z

 

 

 

Field Installed Only

CMC-15

CMC-15

 

 

 

 

 

 

 

 

 

 

 

 

STD

STD

STD

 

 

 

 

z

 

Field Installed Only

CMA-14

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

STD

STD

STD

z

z

 

 

 

z

V

11

Factory Only

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

STD

STD

STD

 

 

 

 

 

z

Field Installed Only

CMA-23 for W18-36A

N/A

 

 

 

 

 

CMA-24 for W42-60A

 

 

 

 

 

 

 

 

 

 

 

 

STD

STD

STD

 

 

 

z

 

 

Field Installed Only

SK111

SK111

 

 

 

 

 

 

 

 

 

 

 

 

 

STD = Standard equipment for these specified models.

1HPC. High pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3.

2 LPC. Low pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3.

3 CCM. Compressor control module has adjustable 30-second to 5-minute delay-on-break timer. On initial power-up, or any time the power is interrupted, the delay-on-make will be 2- minutes plus 10% of the delay-on-break setting. There is no delay-on-make during routine operation of the unit. The module also provides the lockout feature (with 1 retry) for high and/or low-pressure controls, and a 2-minute timed bypass for low-pressure control.

4 LAC. Low ambient control permits cooling operation down to 0°F. LAC is fan-cycling control for outdoor fan motor on all models except W17A1, which is modulating control.

5 ALR. The alarm relay has a set of normally open and normally closed dry contacts to provide the ability to signal a condition of shutdown on either high or low pressure controls.

6 SK. PTCR start kit can be used with all -A single phase models. Increases starting torque 2-3x. Not used for -B or -C three phase models. Do not use if SK111 is used.

7 SK. Start capacitor and potential relay start kit can be used with all -A single phase models. Increases starting torque 9x. Not used for -B or -C three phase models. Do not use if CMC-15 is used.

8 ODT. Outdoor thermostat is adjustable from 0 to 50°F. It is suitable for use as a compressor cut-off thermostat.

9 DDC. Incorporates 4 additional sensors: discharge air temperature, indoor blower airflow, compressor current, and dirty filter. These sensing devices function to input analog data such as temperature, as well as digital data such as airflow, compressor status or filter status. Special economizer required; consult factory.

“V” control module should be ordered in conjunction with direct digital controller (DDC) model TCS24. Refer to DDC specification sheet S3280 for more information.

11Option not available for Model W18A.

12 Use option N for Alarm Relay on Model W18A only.