Air Conditioning Wall-Mount Model Nomenclature
W 36 A 1
A | 10 X | X X | X | X | X |
SERIES
NOMINAL
CAPACITY
17 - 1½ Ton
18 - 1½ Ton
24 - 2 Ton
30 - 2½ Ton
36 - 3 Ton
42 - 3½ Ton
48 - 4 Ton
60 - 5 Ton
REVISION
TYPE
Air Conditioner
Specialty Products 2
VOLTS & PHASE
A - 230/208/60/1
B - 230/208/60/3
C - 460/60/3
KW 1
VENTILATION OPTIONS
(See Table Below)
FILTER OPTIONS
X-
P -
COLOR OPTIONS
X - Beige (Standard)
1 - White
4 - Buckeye Gray
5 - Desert Brown
8 - Dark Bronze
A - Aluminum
S - Stainless Steel
CONTROL MODULES
(See Chart Below)
COIL OPTIONS
X - Standard
1 - Phenolic Coated Evaporator
2 - Phenolic Coated Condenser
3 - Phenolic Coated Evaporator
and Condenser
OUTLET OPTIONS
X - Front (Standard)
T - Top (on W30A and
W36A Models)
1For 0KW and circuit breakers (230/208 Volt) or toggle disconnects (460 Volt) applications, insert 0Z in the KW field of the model number. See Page 8 for available Factory Installed KW options and Page 9 for Field Installed Heater Packages.
2Insert “D” for dehumidification with hot gas reheat — Models W42 - 60 only. See Form
Ventilation Options
Models | W17A1, W18A1, W24A1 |
| W30A1, W36A1 | W42A1, W48A1, W60A1 | |||
Description | Factory Installed | Field Installed | Factory Installed | Field Installed | Factory Installed | Field Installed | |
Code No. | Part No. |
| Code No. | Part No. | Code No. | Part No. | |
|
| ||||||
Barometric Fresh Air Damper - Standard | X |
| X | X | |||
B |
| B | B | ||||
Motorized Fresh Air Damper | M |
| M | M | |||
Commercial Ventilator - Spring Return w/Exhaust | V |
| V | V | |||
Commercial Ventilator - Power Return w/Exhaust |
| P | P | ||||
Economizer - School Versions, Enthalpy 4 | S | S | S | ||||
Economizer - Equipment Bldg., Enthalpy 5 | W | W | W | ||||
Economizer - Equipment Bldg., DB Temp 5 | T | T | T | ||||
Energy Recovery Ventilator - 230 Volt 3 | R | R | R | ||||
Energy Recovery Ventilator - 460 Volt 3 | N/A | 6 | R | R | |||
Door Kit for ERVF (Required) | N/A | WMDK2- | 3 | N/A | WMDK3- 3 | N/A | WMDK5- 3 |
1Intake and exhaust can be independently adjusted.
2Insert color to match unit ("X" = Beige; "4" = Buckeye Gray; etc.)
3WMDK Door Kit must be ordered in addition to ERVF Assembly and ECONWMS & color matched to unit ("X" = Beige; "4" = Buckeye Gray; etc.)
4 Partial Full Flow (75% of Rated Cooling CFM). All ECONWMS versions have 3" deep intake hood.
5 Full Flow (100% of Rated Cooling CFM). ECONWMT 2 and 3 have 16" deep intake hood; ECONWMT- 5 has 18" deep intake hood.
6Model
Air Conditioning Control Modules |
|
|
| All Models Except As Noted | W17A1 | |||||||
|
|
|
|
|
|
|
|
|
|
|
| Factory |
HPC 1 | LPC 2 | CCM 3 | LAC 411 | ALR 5 | SK 6 | SK 7 | ODT 8 | DDC 9 | Factory Installed Code | Field Installed Part | Only | |
|
|
|
|
|
|
|
|
|
|
|
|
|
STD | STD | STD |
|
|
|
|
|
| X |
| N/A | N/A |
|
|
|
|
|
|
|
|
|
|
|
|
|
STD | STD | STD | z |
|
|
|
|
| E | 11 | N/A | |
|
|
|
|
|
|
|
|
|
|
|
|
|
STD | STD | STD | z | z |
|
|
|
| J | 11 | Factory Only | J |
|
|
|
|
|
|
|
|
|
|
|
|
|
STD | STD | STD | z |
| z |
|
|
| K | 11 | N/A | |
|
|
|
|
|
|
|
|
|
|
|
|
|
STD | STD | STD | z | z | z |
|
|
| M | 11 | Factory Only | M |
|
|
|
|
|
|
|
|
|
|
|
| |
STD | STD | STD |
| z |
|
|
|
| N, W18A Only 12 | N/A | N/A | |
|
|
|
|
|
|
|
|
|
|
|
| |
STD | STD | STD |
|
| z |
|
|
| Field Installed Only | |||
|
|
|
|
|
|
|
|
|
|
|
| |
STD | STD | STD |
|
|
|
| z |
| Field Installed Only | N/A | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
STD | STD | STD | z | z |
|
|
| z | V | 11 | Factory Only | N/A |
|
|
|
|
|
|
|
|
|
|
|
|
|
STD | STD | STD |
|
|
|
|
| z | Field Installed Only | N/A | ||
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
| |
STD | STD | STD |
|
|
| z |
|
| Field Installed Only | SK111 | SK111 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
STD = Standard equipment for these specified models.
1HPC. High pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3.
2 LPC. Low pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3.
3 CCM. Compressor control module has adjustable
4 LAC. Low ambient control permits cooling operation down to 0°F. LAC is
5 ALR. The alarm relay has a set of normally open and normally closed dry contacts to provide the ability to signal a condition of shutdown on either high or low pressure controls.
6 SK. PTCR start kit can be used with all
7 SK. Start capacitor and potential relay start kit can be used with all
8 ODT. Outdoor thermostat is adjustable from 0 to 50°F. It is suitable for use as a compressor
9 DDC. Incorporates 4 additional sensors: discharge air temperature, indoor blower airflow, compressor current, and dirty filter. These sensing devices function to input analog data such as temperature, as well as digital data such as airflow, compressor status or filter status. Special economizer required; consult factory.
“V” control module should be ordered in conjunction with direct digital controller (DDC) model TCS24. Refer to DDC specification sheet S3280 for more information.
11Option not available for Model W18A.
12 Use option N for Alarm Relay on Model W18A only.