Cooling Application Data - Outdoor Temperature 1

Model

D.B./W.B.

Cooling

75oF

80oF

85oF

90oF

95oF

100oF

 

105oF

110oF

115oF

 

120oF

 

2

Capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

75/

Total Cooling

17,500

16,700

15,900

15,100

14,300

13,600

 

12,900

12,200

11,600

 

10,800

 

62

Sensible Cooling

13,900

13,500

13,200

12,800

12,500

12,200

 

11,800

11,500

11,100

 

10,700

W17A1

80/

Total Cooling

18,600

18,100

17,600

17,000

16,400

15,800

 

15,200

14,500

13,900

 

13,100

W18A1

67

Sensible Cooling

13,400

13,200

13,000

12,800

12,600

12,400

 

12,100

11,800

11,500

 

11,200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85/

Total Cooling

22,200

21,200

20,200

19,200

18,300

17,300

 

16,400

15,500

14,600

 

13,700

 

72

Sensible Cooling

13,800

13,400

13,100

12,800

12,400

12,000

 

11,600

11,100

10,600

 

10,200

 

75/

Total Cooling

26,000

24,500

23,300

22,100

20,900

20,000

 

19,100

18,400

17,600

 

17,100

 

62

Sensible Cooling

20,100

19,700

19,200

18,800

18,400

17,900

 

17,400

16,900

16,400

 

15,900

W24A1

80/

Total Cooling

27,700

26,700

25,800

24,900

24,000

23,300

 

22,500

21,900

21,200

 

20,700

67

Sensible Cooling

19,500

19,300

19,000

18,800

18,500

18,200

 

17,800

17,400

17,000

 

16,600

 

 

 

 

85/

Total Cooling

33,000

31,200

29,700

28,100

26,700

25,500

 

24,300

23,300

22,300

 

21,500

 

72

Sensible Cooling

20,000

19,600

19,100

18,700

18,200

17,600

 

17,000

16,300

15,700

 

15,000

 

75/

Total Cooling

31,100

29,700

28,300

27,000

25,800

24,700

 

23,700

22,700

21,700

 

20,900

 

62

Sensible Cooling

24,500

24,000

23,500

22,900

22,400

21,800

 

21,300

20,700

20,100

 

19,500

W30A1

80/

Total Cooling

33,200

32,300

31,400

30,400

29,600

28,600

 

27,800

27,000

26,100

 

25,300

67

Sensible Cooling

23,700

23,500

23,200

22,900

22,600

22,200

 

21,800

21,400

20,900

 

20,400

 

 

 

 

85/

Total Cooling

39,600

37,800

36,100

34,500

32,900

31,500

 

30,100

28,800

27,500

 

26,300

 

72

Sensible Cooling

24,300

23,900

23,300

22,800

22,200

21,500

 

20,800

20,100

19,300

 

18,500

 

75/

Total Cooling

38,100

35,900

34,100

32,300

30,800

29,600

 

28,600

27,700

26,900

 

26,400

 

62

Sensible Cooling

28,500

27,800

27,100

26,400

25,800

25,200

 

24,700

24,200

23,700

 

23,200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W36A1

80/

Total Cooling

40,600

39,100

37,800

36,500

35,400

34,500

 

33,700

33,000

32,400

 

32,000

67

Sensible Cooling

27,600

27,200

26,800

26,400

26,000

25,600

 

25,300

25,000

24,600

 

24,300

 

 

 

 

85/

Total Cooling

48,400

45,700

43,400

41,200

39,300

37,800

 

36,400

35,100

34,100

 

33,300

 

72

Sensible Cooling

28,300

27,600

26,900

26,200

25,500

24,800

 

24,100

23,500

22,700

 

22,000

 

75/

Total Cooling

43,600

41,500

39,600

37,600

35,700

33,900

 

32,100

30,400

28,700

 

27,000

 

62

Sensible Cooling

35,500

34,500

33,600

32,700

31,800

31,000

 

30,100

29,200

28,400

 

27,000

W42A1

80/

Total Cooling

46,500

45,200

43,900

42,500

41,000

39,500

 

37,900

36,200

34,500

 

32,700

67

Sensible Cooling

34,400

33,800

33,300

32,700

32,100

31,500

 

30,900

30,200

29,500

 

28,800

 

 

 

 

85/

Total Cooling

55,400

52,900

50,400

48,000

45,600

43,200

 

40,900

38,500

36,300

 

34,000

 

72

Sensible Cooling

35,200

34,300

33,500

32,500

31,500

30,500

 

29,500

28,300

27,200

 

26,000

 

75/

Total Cooling

49,600

47,300

45,100

43,000

40,900

39,000

 

37,100

35,100

33,300

 

31,400

 

62

Sensible Cooling

39,900

39,100

38,200

37,300

36,400

35,500

 

34,500

33,600

32,700

 

31,400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W48A1

80/

Total Cooling

52,900

51,500

50,100

48,600

47,000

45,400

 

43,700

41,900

40,000

 

38,100

67

Sensible Cooling

38,700

38,300

37,800

37,300

36,700

36,100

 

35,400

34,700

34,000

 

33,100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85/

Total Cooling

63,000

60,200

57,500

54,900

52,200

49,700

 

47,100

44,600

42,000

 

39,600

 

72

Sensible Cooling

39,600

38,900

38,000

37,100

36,000

34,900

 

33,800

32,500

31,300

 

29,900

 

75/

Total Cooling

59,200

56,200

53,300

50,500

47,900

45,400

 

43,100

40,800

38,600

 

36,600

 

62

Sensible Cooling

45,200

43,800

42,300

41,000

39,700

38,500

 

37,300

36,100

35,000

 

33,900

W60A1

80/

Total Cooling

63,200

61,200

59,200

57,100

55,000

52,900

 

50,800

48,700

46,500

 

44,300

67

Sensible Cooling

43,800

42,900

41,900

41,000

40,100

39,200

 

38,300

37,300

36,400

 

35,500

 

 

 

 

85/

Total Cooling

75,300

71,600

68,000

64,500

61,100

57,900

 

54,800

51,800

48,900

 

46,000

 

72

Sensible Cooling

44,900

43,600

42,100

40,700

39,300

37,900

 

36,500

35,000

33,500

 

32,100

 

 

 

 

 

 

 

 

 

Capacity Multiplier Factors

 

 

 

 

 

 

 

 

 

% of Rated Airflow

-10

Rated

 

+10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total BTUH

0.975

1.0

 

1.02

 

 

 

 

 

 

 

 

Sensible BTUH

0.950

1.0

 

1.05

1Below 65°F (18.3C), unit requires a factory or field installed low ambient control.

2 Return air temperature.

Form No.

S3397-1112

Supersedes

S3397-712

Page

10 of 12

Page 10
Image 10
Bard W17A, W60A manual Cooling Application Data Outdoor Temperature, Capacity Multiplier Factors