WALL MOUNT GENERAL INFORMATION
AIR CONDITIONER WALL MOUNT MODEL NOMENCLATURE
W 42 A 2 – A 10
X X X X X A
MODEL NUMBER
CAPACITY
17- 1½ Ton
18- 1½ Ton
24- 2 Ton
30- 2½ Ton
36- 3 Ton
42- 3½ Ton
48- 4 Ton
60- 5 Ton
70- 6 Ton
REVISIONS
KW
VOLTS & PHASE
A - 230/208/60/1
B - 230/208/60/3
C - 460/60/3
A- Right Hand Air Conditioner L - Left Hand Air Conditioner
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| CONTROL MODULES | |||
|
|
|
|
|
|
|
|
|
|
| (See Spec. Sheet S3397) | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| COIL OPTIONS | ||||||
COLOR OPTIONS |
| X - Standard | ||||||||||||
X - | Beige (Standard) | 1 | - Phenolic Coated Evaporator | |||||||||||
1 | - | White | 2 | - Phenolic Coated Condenser | ||||||||||
4 | - | Buckeye Gray | 3 | - Phenolic Coated Evaporator | ||||||||||
5 | - | Desert Brown |
|
|
| and Condenser | ||||||||
6 | - | Dark Bronze |
|
|
|
|
|
|
|
|
A - Aluminum | OUTLET OPTIONS |
S - Stainless Steel | X - Front (Standard) |
VENTILATION OPTIONS
X- Barometric Fresh Air Damper (Standard) B -
M - Motorized Fresh Air Damper
V - Commercial Ventilator - Motorized with Exhaust
R - Energy Recovery Ventilator - Motorized with Exhaust (See Spec. Sheet S3397)
S - Economizer - School Versions, Enthalpy W - Economizer - Equipment Building, Enthalpy T - Economizer - Equipment Building, DB Temp.
T - Top Outlet (W30A, W36A Only) |
FILTER OPTIONS
X- One Inch Throwaway (Standard) W - One Inch Washable
P - Two Inch Pleated
NOTE: Vent options X, B and M are without exhaust capability. May require separate field supplied barometric relief in building.
SHIPPING DAMAGE
Upon receipt of equipment, the carton should be checked for external signs of shipping damage. If damage is found, the receiving party must contact the last carrier immediately, preferably in writing, requesting inspection by the carrier’s agent.
GENERAL
The equipment covered in this manual is to be installed by trained, experienced service and installation technicians.
The refrigerant system is completely assembled and charged. All internal wiring is complete.
The unit is designed for use with or without duct work. Flanges are provided for attaching the supply and return ducts.
These instructions explain the recommended method to install the air cooled
These instructions and any instructions packaged with any separate equipment required to make up the entire air conditioning system should be carefully read before beginning the installation. Note particularly “Starting Procedure” and any tags and/or labels attached to the equipment.
While these instructions are intended as a general recommended guide, they do not supersede any national and/or local codes in any way. Authorities having jurisdiction should be consulted before the installation is made. See Page 3 for information on codes and standards.
Size of unit for a proposed installation should be based on heat loss calculation made according to methods of Air Conditioning Contractors of America (ACCA). The air duct should be installed in accordance with the Standards of the National Fire Protection Association for the Installation of Air Conditioning and Ventilating Systems of Other Than Residence Type, NFPA No. 90A, and Residence Type Warm Air Heating and Air Conditioning Systems, NFPA No. 90B. Where local regulations are at a variance with instructions, installer should adhere to local codes.
Manual | |