Bard w17a2 W**A Right Unit, W**L Left Unit, Condenser Air Outlet, Supply Air Opening, Inlet

Models: w17a2

1 26
Download 26 pages 40.89 Kb
Page 7
Image 7
FIGURE 2

FIGURE 2

Dimensions of Basic Unit for Architectural and Installation Requirements (Nominal)

MODEL

WIDTH

DEPTH

HEIGHT

SUPPLY

RETURN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(W)

(D)

(H)

A

B

C

B

E

F

G

I

J

K

L

M

N

O

P

Q

R

S

T

 

W17A, L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W18A, L

33.300

17.125

70.563

7.88

19.88

11.88

19.88

35.00

11.00

25.75

20.56

26.75

28.06

29.25

27.00

2.63

34.13

22.06

10.55

4.19

12.00

5.00

W24A, L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W30A, L

38.200

17.125

70.563

7.88

27.88

13.88

27.88

40.00

11.00

25.75

17.93

26.75

28.75

29.25

27.00

2.75

39.19

22.75

9.14

4.19

12.00

5.00

W36A, L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W42A, L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W48A, L

42.075

22.432

84.875

9.88

29.88

15.88

29.88

43.88

13.63

31.66

30.00

32.68

26.94

34.69

32.43

3.37

42.88

23.88

10.00

1.44

16.00

1.88

W60A, L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W70A, L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All dimensions are in inches. Dimensional drawings are not to scale.

W**A

RIGHT

UNIT

5.88

F

G

W

Filter Access Panel

Ventilation Air

Condenser

Air Outlet

Front View

 

Built In

D

 

 

 

E

 

 

1

 

 

 

O

 

 

Rain Hood

7.88

 

 

 

 

 

 

 

 

31.88 1

 

 

4° Pitch

 

1

 

 

 

Heater

 

1.00

 

.44

 

 

Access

 

2.13

 

 

 

 

Panel

 

Side Wall

 

R

 

Electric

 

A

 

Supply Air Opening

 

 

 

 

 

Heat

 

 

Mounting

 

 

 

C. Breaker/

 

 

 

Brackets

 

 

 

 

 

 

(Built In)

 

S

 

Disconnect

 

 

 

B

Access Panel

 

I

 

Top Rain

 

 

 

(Lockable)

 

 

 

 

 

Hood for ERV and

 

 

 

Flashing

 

S

ECONWMS models

 

 

 

Shipping

 

only

 

 

 

 

Location

 

 

 

 

 

C

H

Optional

Return Air Opening

 

Standard

3"

 

Electrical

S

flush vent

 

 

 

Entrances

 

 

door for

 

 

 

 

 

 

 

non-ERV/

 

 

 

 

 

 

 

Econ.

 

 

 

 

 

 

S

models

11"

 

 

 

 

 

 

 

 

 

 

 

 

 

K

 

 

 

 

Hood for

Low Voltage

Cond.

 

L

 

 

Electrical

J

 

M

 

S

ECONWMT

Entrance

Air

 

 

 

models.

High Voltage

Inlet

 

 

P

 

 

 

Electrical

 

 

 

 

 

 

 

Entrance

 

 

 

 

 

T

Drain

N

 

Back View

Bottom Installation

Side View

 

Q

Bracket

MIS-2487 G

jOptional top outlet (factory installed only) for W30A and W36A models only.

W**L

LEFT

UNIT

Manual

2100-581B

Page

7 of 26

Page 7
Image 7
Bard w17a2 W**A Right Unit, W**L Left Unit, Condenser Air Outlet, Supply Air Opening, Return Air Opening, Inlet