WARNING
Insure the cylinder valve is CLOSED (valve turned clockwise) prior to connecting the LP gas cylinder to your cooker. Turn the regulator control knob
CONNECTING REGULATOR HOSE ASSEMBLY TO LP GAS CYLINDER
1.Check that cylinder is upright and the valve is closed by turning the knob clockwise.
2.Remove the protective safety cap from the cylinder valve and the
3.Insert the nipple of the large coupling nut into the valve outlet. Insure that the coupling nut is centered properly.
4.Turn the large coupling nut clockwise by hand and tighten to a full stop. Take care not to cross thread the coupling nut onto the cylinder valve. Do not
Upright | Turn Coupling Nut |
CLOCKWISE | |
position | to Attach |
| Hand Tighten! |
Turn Knob
NOTE: If you are unable to make the connection, repeat steps 3 and 4.
5.Check that the hose does not contain kinks, does not come into contact with sharp edges, and does not contact surfaces that may become hot during use.
6.Leak check all fittings before lighting cooker. See section on "Gas Leak Test Instructions" on page 13.
GAS LEAK TESTING
DANGER
LEAK TESTING
To prevent fire or explosion hazard:
•DO NOT smoke or permit ignition sources in the area while conducting a leak test.
•Perform test OUTDOORS only in a well ventilated area.
•Never perform a leak test with a match or open flame.
•Never perform a leak test while the cooker is in use or while cooker is still hot.
WARNING
WHEN TO PERFORM A LEAK TEST
•After assembling your cooker and before lighting for the first time, even if purchased fully assembled.
•Every time the LP gas cylinder is refilled or if any of the gas components are replaced.
•Any time your cooker has been moved.
•At least once per year or if your cooker has not been used for more than 60 days.
13