Installing a Series System
Installing a Series System
WARNING
Xantrex Technology recommends that all wiring be completed by a certified technician or electrician to ensure adherence to approved electrical wiring regulations.
WARNING: Fire, Shock, and Energy hazard
Make sure wiring is disconnected from all electrical sources before you handle. All wiring must be done in accordance with local and national electrical wiring codes. Do not connect the output terminals of the PROsines to any incoming AC sources.
•Xantrex recommends that you have an electrician set up the two PROsines because knowledge of the electrical code,
•See page
•See “Step 1: Designing the Installation” on page
•Connect the system as shown in Figure
Detailed procedures for setting up an AC series system are given below.
Connecting AC Input Wiring
To connect each PROsine to the utility 120/240Vac
1.Assign one PROsine to Line 1 and one to Line 2 and maintain the same assignment throughout the AC input and AC output wiring steps.
2.Connect
3.Run the
•The Line 1 conductor to its AC Input Line conductor (black)
•The neutral to its AC Input neutral conductor
•The ground to its AC Input ground terminal
4.Repeat steps 2 and 3, connecting the 30A breaker on Line 2, neutral, and
ground from the source panel to the input wires and ground of the L2 PROsine.