Specifications

Electrical Specifications: Invert Mode

DC Input

 

 

 

Operating voltage range

10.0V–16.0V

 

 

Safe non-operating voltage range

0–18Vdc

 

 

Nominal current at full load

200A

 

 

AC Output

 

 

 

Output voltage

117Vac

 

 

Continuous power

2.0kW, 2.0kVA to 40°C max. ambient

 

 

Surge power

4.5kW for 5s

 

 

Max short-circuit current

55Arms, 55Apk

 

 

Frequency

60.0Hz ±0.05%

 

 

Wave shape

Sine

 

 

THD (over load range of 0–2.0kW

≤2%

resistive)

 

 

 

Power derating above 40°C ambient temp

See “Invert Power Derating vs. Ambient

 

Temperature” on page A–6.

 

 

Peak efficiency

≥87%

 

 

Full load efficiency

≥83%

 

 

Other

 

 

 

Load power factor range

0–1, inductive, capacitive, or nonlinear, to

 

2kVA

 

 

No load input power (producing output

≤25W

voltage)

 

 

 

Load sense power

≤4W (1s interval) ≤2W (3s interval)

 

 

Standby mode power draw

≤0.5W

(no output, display off)

 

 

 

Off mode current draw

≤2mA

 

 

A–2

445-0089-01-01

Page 122
Image 122
Xantrex Technology PROsine 2.0 user manual Electrical Specifications Invert Mode, DC Input, AC Output, Other