Xantrex Technology PROsine 2.0 user manual WARNING Shock hazard, Auto Restart After Error

Models: PROsine 2.0

1 148
Download 148 pages 27.01 Kb
Page 78
Image 78
Auto Restart After

Configuration

Auto Restart After

Error

 

 

WARNING: Shock hazard

 

 

If Auto Restart is selected, AC voltage can reappear at the loads without notice after a

 

 

fault has occurred and cleared.

 

 

 

 

 

If you select Yes, the PROsine will attempt to restart (five attempts) after a fault

 

 

has occurred.

 

 

If you select No, the PROsine ceases operation when an error occurs. It then

 

 

requires that you manually restart the unit by going to the Configuration menu

 

 

and clearing the error.

 

 

Exception: If the PROsine shuts down in Invert mode because of low battery and

 

 

the charger is enabled and AC is then supplied to the PROsine, it will

 

 

automatically charge the battery.

Reset to Defaults

You can only apply Load Factory, Save as Custom, or Load Custom if both the

 

 

charger and the inverter are disabled. The display panel should respond with OK.

 

 

If Error appears, disable invert and charge and try again.

Load Factory

If you select Load Factory, all PROsine settings will be reset to their default

 

 

values.

Save Custom

If you want to change the settings temporarily, you may want to save your current

 

 

system settings. To save the current configuration of the PROsine, select Save

 

 

Custom. You can then restore this configuration to the PROsine at a later time.

Load Custom

Select Load Custom to restore your custom settings to overwrite the current

 

 

PROsine settings.

4–10

445-0089-01-01

Page 78
Image 78
Xantrex Technology PROsine 2.0 user manual WARNING Shock hazard, Auto Restart After Error