Part 3: Configuration Options
Diagnostics Menu
Menu Items | Access | |
|
| |
PS System Mode | ||
|
| |
View Last 20 PROsine Faults |
| |
• | PROsine Fault #0 | |
• — |
| |
• | PROsine Fault #19 |
|
|
| |
Clear PROsine Fault Log | User | |
|
| |
View Last 10 Panel Faults |
| |
• | Panel Fault #0 | |
• — |
| |
• | Panel Fault #9 |
|
|
| |
AC Bad Cause | ||
|
| |
View Software Versions: |
| |
• | LVP Software Revision |
•HVP Software Revision
•Display Software Revision
•Display EEPROM Revision
View System Temperatures:
• | Panel ambient temp | |
• | Unit Temp #1 |
|
• | Unit Temp #2 |
|
|
| |
PROsine HVDC |
Menu Choices or Information Displayed
| The screens on the Diagnostics menu are |
| troubleshoot the status of your PROsine system. For example, if the unit is |
| continually recording Warnings about low battery voltage, you can view the |
| messages and take appropriate corrective action. |
| The following items appear on this menu: |
PS System Mode | This screen indicates the present operating mode of the PROsine: invert, bulk |
| charge, absorption charge, etc. |
View Last 20 | The PROsine records the last twenty PROsine Warnings and Errors. You can |
PROsine Faults | examine these for diagnostic and troubleshooting purposes. See Chapter 6, |
| “Troubleshooting”. |
| Warnings end with these characters: |
| are displayed in the same way without the |
Clear PROsine | When reviewing a log containing errors it is not always clear what faults are |
Fault Log | recent and which are old and not relevant. Select "OK" to clear all entries in the |
| PROsine fault log - after this any errors in the log must be recent. |