Inverter Overload Operation
Inverter Overload Operation
This graph shows how long the PROsine will operate for given output current.
Time to Shutdown vs. Current
| 10000.00 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1000.00 |
|
|
|
|
|
| Unit shuts dow n sooner for |
|
|
| ||||||
|
|
|
|
|
|
|
| higher internal heatsink |
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||
(s) | 100.00 |
|
|
|
|
|
|
|
| temperature. |
|
|
|
|
| ||
10.00 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Time |
|
|
|
|
|
|
|
|
| T<60°C |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
1.00 |
|
|
|
|
|
|
|
|
| 60<T<80°C |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| 0.10 |
|
|
|
|
|
|
|
|
| T>80°C |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 0.01 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 15 | 20 | 25 | 30 | 35 | 40 | 45 | 50 | 55 | 60 | 65 | 70 | 75 | 80 | 85 | 90 | 95 |
AC Output Current (A rms)
Typical Inverter Efficiency
Inverter Efficiency
| 95 |
|
|
|
|
|
|
(%) | 90 |
|
|
|
|
| 14Vdc |
85 |
|
|
|
|
| 12Vdc | |
Efficiency |
|
|
|
|
| ||
80 |
|
| ` |
|
| 10Vdc | |
|
|
|
|
|
|
| |
| 75 |
|
|
|
|
|
|
| 70 |
|
|
|
|
|
|
| 0 | 500 | 1000 | 1500 | 2000 | 2500 | 3000 |