Introduction

Table 1-1PROsine Default Values

Item

Default Value

 

 

Your Settings

Adjustable From the Configure Battery Menu

NOTE

Settings below are for Battery Type = Generic Gel.

Battery Size

200Ah

**

Default Battery Temperature

Warm

 

Battery Type

Generic Gel

**

Battery Temp. Coefficient

–27mV/°C

 

Bulk Mode Settings:

14.2V

 

Max Voltage

 

Max Current (%C)

25%

 

Threshold Voltage

13.8V

 

Threshold Timeout

3min

 

Absorption Mode Settings:

14.2V

 

Max Voltage

 

Max Current (%C)

25%

 

Max Timeout

8hr

 

Threshold Current (%C)

1%

 

Threshold Timeout

3min

 

Overcharge Mode Settings:

 

 

 

Max Voltage

14.2V

 

Max Current (%C)

20%

 

Max Timeout

0

 

Float Mode Settings:

13.8V

 

Max Voltage

 

Max Current (%C)

200%

 

Max Timeout

21days

 

Threshold Voltage

12.5V

 

Threshold Timeout

15min

 

Equalize Mode Settings:

13.8V

 

Max Voltage

 

Max Current (%C)

200%

 

Max Timeout

0

 

Threshold Voltage

0

 

Threshold Timeout

0

 

Constant Mode Settings:

 

 

 

Voltage Setpoint

13.5V

 

Current Setpoint

100A

 

Charger Mode

Standalone

 

Charger Type

3-Step

 

Charger High Battery V

1.0V

 

Warning Offset

 

 

 

 

 

 

 

 

NOTE

The values opposite the gray bar are set when you select a battery type. If you did not subsequently change these settings, they do not need to be recorded.

1–10

445-0089-01-01

Page 30
Image 30
Xantrex Technology PROsine 2.0 user manual Adjustable From the Configure Battery Menu