Table 4-1Menu Structure—Overview

 

 

 

 

 

Part 2: Configuration Menus and Screens

 

 

 

 

 

 

 

 

 

Table 4-1Menu Structure—Overview

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Configure PROsine—Basic

Configure PROsine—Advanced

Configure Display Panel

Configure Battery

Diagnostics

 

 

 

 

 

 

 

 

 

AC Breaker Size

Load Sensing

Audible Alarm

Battery Size

PS System Mode

 

 

Load Sensing

Load Sense Power

LCD Backlight Mode

Default Battery Temp

View Last 20 PROsine Faults

 

 

Equalize

Load Sense Interval

LCD Backlight Brightness

Battery Type

Clear PROsine Fault Log

 

 

 

Low AC Transfer (V)

LCD Backlight Timeout

View/Change Battery Details:

View Last 10 Panel Faults

 

 

 

Low AC Transfer (Hz)

Temperature (C/F)

Battery Temp. Coefficient

AC Bad Cause

 

 

 

High AC Transfer (V)

 

Bulk Charge Mode Settings

View Software Versions:

 

 

 

High AC Transfer (Hz)

 

Max Voltage

LVP Software Revision

 

 

 

AC Series Mode

 

Max Current (%C)

HVP Software Revision

 

 

 

Inverter Low V Shutdown

 

Threshold Voltage

Display Software Revision

 

 

 

 

Threshold Timeout

 

 

 

Inverter Low V Warning

 

Display EEPROM Revision

 

 

 

 

Absorption Mode Settings:

 

 

 

Inverter Low V Restart Hysteresis

 

View System Temperatures:

 

 

 

 

Max Voltage

 

 

 

Run Without Panel

 

Max Current (%C)

Temperature at Panel

 

 

 

Inverter After Reset Without Panel

 

Max Timeout

• PROsine Unit Temp. 1

 

 

 

Charger After Reset Without Panel

 

Threshold Current (%C)

 

 

 

 

• PROsine Unit Temp. 2

 

 

 

Auto Restart After Error

 

Threshold Timeout

 

 

 

 

Overcharge Mode Settings:

PROsine HVDC

 

 

 

Reset to Defaults

 

 

 

 

 

Max Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max Current (%C)

 

 

 

 

 

 

 

Max Timeout

 

 

 

 

 

 

 

Float Mode Settings:

 

 

 

 

 

 

 

Max Voltage

 

 

 

 

 

 

 

Max Current (%C)

 

 

 

 

 

 

 

Max Timeout

 

 

 

 

 

 

 

Threshold Voltage

 

 

 

 

 

 

 

Threshold Timeout

 

 

 

 

 

 

 

Equalize Mode Settings:

 

 

 

 

 

 

 

Max Voltage

 

 

 

 

 

 

 

Max Current (%C)

 

 

 

 

 

 

 

Max Timeout

 

 

 

 

 

 

 

Threshold Change

 

 

 

 

 

 

 

Threshold Timeout

 

 

 

 

 

 

 

Constant Mode Settings:

 

 

 

 

 

 

 

Voltage Setpoint

 

 

 

 

 

 

 

Current Setpoint

 

 

 

 

 

 

 

Charger Mode

 

 

 

 

 

 

 

Charger Type

 

 

 

Charger High Battery V Warning Offset