Default Values for the PROsine System

Default Values for the PROsine System

Table 1-1 lists the default settings for the PROsine system. Record your settings in the right-hand column after you have configured the PROsine. This information will be valuable if you need to reconfigure your system or call Xantrex Customer Service

Table 1-1PROsine Default Values

Item

NOTE

Default Value

Your Settings

At a minimum, configure the items marked with a ** after installation.

Adjustable From the Configure PROsine—Basic Menu

AC Breaker Size

15 amps

**

Adjustable From the Configure PROsine—Advanced Menu

Load Sensing

Disabled

 

Load Sense Power

100 Watts

 

Load Sense Interval

1 second

 

Low AC Transfer (V)

90V

 

Low AC Transfer (Hz)

55Hz

 

Hi AC Transfer (V)

130V

 

Hi AC Transfer (Hz)

65Hz

 

AC Series Mode

Standalone

 

Inverter Low V Shutdown

10V

 

Inverter Low V Warning

+0.5V

 

Iverter Low V Restart

2.5V

 

Hysteresis

 

 

Run Without Panel

NO

 

Inverter Enabled on Reset

Disabled

 

Without Panel

 

 

Charger Enabled on Reset

Disabled

 

Without Panel

 

 

Auto Restart After Error

NO

**

 

 

Adjustable From the Configure Display Panel Menu

 

 

 

 

Audible Alarm

OFF

 

LCD Backlight Mode

Auto

 

LCD Backlight Brightness

50%

 

LCD Backlight Timeout

20 seconds

 

Temperature

Farenheit

 

 

 

 

445-0089-01-01