Warning Messages

Table 6-2Warning Messages

Warning Message

Details

Action

 

 

 

Inv Hi Bat V -W

High battery voltage, invert mode.

Check for external charging sources and disable

 

 

Chg Hi Bat V -W

Battery voltage exceeds 15.5V in

if necessary.

 

charge mode.

 

 

 

 

AC In Rev Pol -W

Input AC line and neutral wiring

The unit will continue to operate. For safest

 

polarity is reserved. Check to see that

operation, however, you should correct the AC

 

the Line side of the AC source

input wiring

 

(shorepower) has a voltage to ground

 

 

and the neutral side does not. May also

 

 

occur if the shorepower neutral is

 

 

floating (not connected to earth)

 

 

 

 

AC Out Ovrload -W

AC output overload.

Reduce the AC load so that even for short times,

 

 

AC output current does not exceed 26A.

 

 

 

Low AC In V -W

AC input voltage too low.

Check for bad cabling.

 

 

There may be too many loads on the AC supply

 

 

line.

 

 

Reduce the AC dropout level.

 

 

 

High AC In V -W

AC input voltage too high.

Check the AC input (shorepower) source voltage

 

 

and correct if necessary or raise the AC input

 

 

high voltage limit.

 

 

 

Bat Temp Short -W

Battery temperature sensor short

Install a new sensor.

 

detected.

 

 

 

 

Memory Warning

EEPROM memory CRC is incorrect

Call Xantrex.

 

 

 

Equalizing!

The unit is equalizing.

Refer to page 5–8: disconnect any sensitive

 

 

loads and monitor battery electrolyte level and

 

 

S.G. throughout.

 

 

 

Unit attempting to

Auto Restart After Error has been

The unit will re-start and provide 120VAC

restart.

enabled, the error has cleared, and the

output without warning.

 

unit is restarting.

Disconnect any AC loads that could be

 

 

hazardous if they were to become re-energized

 

 

without warning.

 

 

 

445-0089-01-01

6–5

Page 101
Image 101
Xantrex Technology PROsine 2.0 user manual 2Warning Messages