Xantrex Technology PROsine 2.0 user manual 3 Error Messages, Details, Action

Models: PROsine 2.0

1 148
Download 148 pages 27.01 Kb
Page 103
Image 103
Error Messages

 

 

Error Messages

 

 

 

Table 6-3Error Messages

 

 

 

 

Error Message

Details

Action

 

 

 

Invert Hi Bat V

Inverter battery voltage greater than

Check for external charging sources and disable

 

16V.

if necessary.

 

 

 

AC Out Overload

AC output overload.

Reduce the AC load so that even for short times,

 

 

the AC output current does not exceed 26A.

 

 

 

Ext Comm Timeout

PROsine external communications

Check that the connections on the

 

timeout

communications cable between the PROsine and

 

 

the display panel are secure.

 

 

Check whether the communications cable has

 

 

been damaged.

 

 

Check the proximity of the communications

 

 

cable to DC and AC cables. If the cable crosses

 

 

DC or AC cables, ensure that it does so at right

 

 

angles.

 

 

 

Charge Lo Bat V

Battery voltage did not rise above 10V

Clear the error and restart the charging process.

 

within 30 seconds of the charger

If battery V does not come to 10V after a few of

 

starting. This may indicate a problem

charging cycles, have your battery tested.

 

with the battery (e.g. a damaged

 

 

battery), but will also occur if the

 

 

battery was very dead at the start of the

 

 

charge cycle.

 

 

 

 

SeriesComTimeout

Series communication timeout

Ensure that both PROsines have power.

 

 

Ensure that the ON/OFF/REM switch for both

 

 

units is ON (or REM if Remote Shutdown is

 

 

being used).

 

 

Ensure that both PROsines are configured

 

 

correctly and are enabled.

 

 

 

RelayWeldDetect0

The internal transfer relay is unable to

 

 

switch between shorepower and

 

RelayWeldDetect1

 

inverter output. Charge/passthrough or

Call Xantrex.

 

RelayWeldDetect2

Invert modes may be unavailable.

 

 

 

 

AC Backfeed

You have applied an AC source

Check AC input and output wiring. The AC

 

(shorepower) to the inverter output.

output wiring should not be connected to an AC

 

This has been caused by improper

source at any time.

 

wiring. This error can also be caused by

 

 

a short circuit on the AC output wiring.

 

 

 

 

445-0089-01-01

6–7

Page 103
Image 103
Xantrex Technology PROsine 2.0 user manual 3 Error Messages, Details, Action