SUPERSCAN ACTIVE INFRARED PRESENCE BEAM

The SuperScan safety detector is a presence detection system that is primarily utilized on automatic pedestrian swing doors. B.E.A., Inc. has found ways that the SuperScan can be utilized on industrial doors.

The electronic components come housed in a narrow aluminum extrusion that measures 34.5" and can be altered to accommodate different door widths. The system comes complete for mounting to the door and includes a door loop, which encases the wiring from the door to the door jamb.

Detection zones can be varied in range by a potentiometer adjustment, and in width by adding or taking away slave modules from the master. These slave modules are simply added by inserting them into the aluminum extrusion then connecting them with the attached flat ribbon cable to the next module. This can be done without interrupting other modules in the same extrusion. Once installed, the zone (in addition to being adjustable for distance) can be angled independently from the other modules. This means that the zone can be directed closer or farther away from the face of the door.

Each SuperScan module consists of two optics, a transmitter (TX) and a receiver (RX), and functions independently of the other modules. The transmitter emits an extremely precise beam, which measures approximately 4" in diameter at a distance of 8'. The receiver in turn receives the infrared beam reflected off of the floor or other reflecting surface. This transmission and reception forms a detection angle, which is the basic premise of detection (called triangulation). Should this angle be interrupted, detection will occur. Detection is NOT based upon the intensity of the beam, and in principle will not be affected by the color of the object that interrupts the angle. Background color will not alter the performance of detection.

PLEASE NOTE: The SuperScan is water-resistant but not water-proof. Direct water spray is not recommended. Any units sent back to B.E.A. with water damage would be 100% out of warranty.

TECHNICAL SPECIFICATIONS

Power Supply

Output Relay: 12-24 V AC/DC ± 10%

Current Consumption:

Master: On = 60 mA max.

 

Master: Off = 30 mA max.

 

Slave: On = 40 mA max.

 

Slave: Off = 30 mA max.

Input Inhibit

12-24 V AC/DC ± 10%: Active when voltage is applied

Input Monitoring

12-18 V DC: Active when voltage is removed

Output Interface; relay

Relay; max. contact rating is 1A @ 30V ( resistive)

Detection Range

0' to 8'2" (2.5 m)

Distance Adjustment

2 ft. up to 8 ft. (.61m up to 2.44m) rotating cam with linear

 

adjustment

Detection Time

< 50 ms

Detection Signal Duration

Infinite Presence Detection

Output Hold Time

Potentiometer Range: 0.1 sec. to 4.5 secs.

LED Indications

Master: Red LED = Detection

 

Green LED = Active Output

 

Slave: Red LED = Detection

Operating Temperature Range

-30° F to 140° F

PCB Dimensions

Master: 10.91" x 1.5" (277mm x 38mm)

 

Slave: 8.75" x 1.5" (222mm x 38mm)

Connection to Door Controller

8 Position Screw Terminal on Master PCB

Connection: Master to Slave

Flat Ribbon Cable With Connectors and Key Lock

Max. Number of Slaves

Standard = 9 / With Monitoring = 8 max.

Functions Selection

Detection Mode - NO or NC

 

Standard Mode or With Protection Against Masking

75.1035 V1 Feb 2001