PASSIVE RELAY: The relay is de-energized when the detector is at rest

1. NORMALLY OPEN: Use NO & COM terminals (4 & 6) & CHANGE JP2 from the factory preset position.

Contact closed if detection (green led ON , red led ON)

2. NORMALLY CLOSED: Use the NC & COM terminals (5 & 6) & CHANGE JP2 from the factory preset position.

Contact open if detection (green led ON, red led ON)

Potentiometer P1: Hold Time

Adjustment

The hold time adjustment is altered by the turn of a potentiometer, and refers to the amount of time the output may be held. A range of 100 mS to 4.5 seconds can be obtained. Clockwise rotation increases hold time.

Mounting

Angles

HINGE SIDE RIGHT

HINGE SIDE LEFT

Angles of 0° through 10° shown below

Angles of 15° through 25° shown below

Top View

10º

Adjustable angles15º

5

from 0º to 25º.

20º

25º

NOTE: On the approach side, it is recommended to choose the proper mounting angle as well as proper detection distance depending on the application, the # of modules used, and the width of the door.