Wiring Connections for Industrial Use

Terminals

 

1

 

NOTE USED

2

 

NOT USED

3

 

NOT USED

4

(NO)

In the relay mode, depending on the position of JP2 this terminal will provide either a NO or NC

 

 

contact.

 

 

Please see page 9 for further explanation.

5

(NC)

In the relay mode, depending on the position of JP2 this terminal will provide either a NO or NC

 

 

contact.

 

 

Please see page 9 for further explanation.

6

(COM)

Common contact for relay.

7

(-)

This terminal is used for power input in the relay version of operation. A voltage of 12 to 24

 

 

volts AC or DC ± 10% should be supplied and if voltage drops below the minimum (12v -10%)

 

 

the detector will not function.

8

(+)

This terminal is used for power input in the relay version of operation. A voltage of 12 to 24

 

 

volts AC or DC ± 10% should be supplied. Consumption under 12 volts will be 60 mA for the

 

 

master module plus 40 mA for the slave module.

If after troubleshooting a problem, a satisfactory solution cannot be achieved, please call B.E.A., Inc. for further assistance during Eastern Standard Time at

1-800-523-2462 from 7am - 5pm or 1-800-407-4545 from 5pm - midnight & weekends.

DO NOT leave any problem unresolved. If you must wait for the following workday to call B.E.A.,

leave the door inoperable until satisfactory repairs can be made. NEVER sacrifice the safe

operation of the automatic door or gate for an incomplete solution.