FALCONDR /FALCONXL-DR
USER’S GUIDE
MOTION SENSORS FOR INDUSTRIAL DOORS
FALCON DR: double relay / high mount • FALCON
TECHNICAL SPECIFICATION
Technology | : Microwave and |
Transmitter frequency | microprocessor |
: 24.125 GHz | |
Transmitter radiated power | : <20 dBm EIRP |
Transmitter power density | : < 5 mW/cm² |
Mounting height | : from 11.5’ (3.5m) to 23’ (7m) |
• FALCON DR | |
• FALCON | : from 6.5’ (2m) to 11.5’ (3.5m) |
Tilt angles | : 0° to 180° in elevation |
Detection zone | : 13’ (W) x 16’ (D) |
• FALCON DR | |
(mounting height of 5m) | 4m (W) x 5m (D) |
• FALCON | : 13’ (W) x 6.5’ (D) |
(mounting height of 2.5m) | 4m (W) x 2m (D) |
Detection mode | : Motion |
Minimum speed | : 2 in (5cm)/s (measured in the |
Supply voltage | sensor axis) |
: 12V to 24V AC ±10% | |
Mains frequency | 12V to 24V DC +30% / |
: 50 to 60 Hz | |
Power consumption | : < 2W (VA) |
Two Output relay (free of potential | |
• Max. contact voltage | : 42V AC |
• Max. contact current | : 1A (resistive) |
• Max. switching power | : 30W (DC) / 60VA (AC) |
Hold time | : 0.5s to 9s (adjustable) |
Temperature range | : |
Degree of protection | : IP65 |
Norm conformity | : R&TTE 1999/5/EC |
Dimensions | EMC 89/336/EEC |
: 4” (W) x 5” (D) x 3 ¾” (H) | |
Weight | 102 mm (W) x 127 mm (D) x 96 mm (H) |
: 0.88 lbs (0.4 kg) | |
Material of housing | : ABS and polycarbonate |
Material of bracket | : Anodized aluminium |
Length of cable | : 33’ (10m) |
Manual adjustment |
|
•Orientation of sensing field (mechanically)
•Multiple functions (by push buttons)
Remote control adjustments
•Sensitivity
•Hold time
•Detection mode
•Pedestrian and parallel traffic rejection mode
•Output configuration
•Security
DESCRIPTION OF
THE SENSOR
Tranceiver module (planar antenna)
Green LED
Infrared Receiver
Red LED
2 Push Buttons
Microprocessor
Terminal block
INSTALLATION
TIPS
The sensor must be firmly fastened to prevent from vibrating.
The sensor must not be placed directly behind a panel or any kind of material.
The sensor must not have any object likely to move or vibrate in its sensing field.
The sensor must not have any fluorescent lighting in its sensing field.
75.5268.01 20070111 | Page 1 of 7 |