24

Trouble Shooting Guide

Burner Will Not Start

 

 

 

 

Thermostat Set

No

Adjust

Above Room

 

Thermostat

Temperature

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

High Limit Set on

No

Adjust High

Aquastat to 180

 

Limit

Deg. Min.

 

 

 

 

Yes

 

 

 

 

 

 

110 Volts between

No

L1 and L2 at

 

 

Aquastat

 

 

Yes

 

 

 

 

110 Volts between No

B1 and B2 at

Aquastat

Yes

Check Fuses and

Safety Switches

Remove Thermostat

Wires From Aquastat and

Jumper T T terminals.

Aqustat Relay Energizes

Yes

No

Aquastat

No

in Fault

 

 

 

 

Condition

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

Check Thermostat

Circuit

Refer to

Aquastat Manual

110 Volts at

Burner

Yes

Refer to Oil

Burner Manual

No

Check Molex

Connector

110Volts

Between B1 and B2 at Aquastat

Yes

No

Replace Aquastat

Page 24