Beckett SL375, SLD375, SL5125, SLD4100, SLD5125, SL7175, SL4100, SL6150 manual Ratings and Data

Models: SL6150 SL4100 SL7175 SL375 SLD5125 SLD4100 SL5125 SLD375

1 32
Download 32 pages 25.29 Kb
Page 4
Image 4
Ratings and Data

4

Ratings and Data

Boiler Model No.

SL375

SLD375

SL4100

SLD4100

SL5125

SLD5125

SL6150

SL7175

Firing Rate - #2 Fuel

0.75

0.75

1.00

1.00

1.25

1.25

1.50

1.75

Input BTU/HR

105,000

105,000

140,000

140,000

175,000

175,000

210,000

245,000

DOE Capacity BTU/HR

91,000

91,000

122,000

122,000

153,000

153,000

184,000

208,250

Net IBR Rating BTU/HR

79,000

79,000

106,000

106,000

133,000

133,000

160,000

181,100

Net Rating Sq. Ft.

526

526

707

707

887

887

1,067

1,207

AFUE Rating

85.5

85.5

86.5

86.5

86.9

86.9

86.9

85.0

Water Capacity

3.6

3.6

4.3

4.3

5.1

5.1

5.8

6.5

Approx. Shipping Weight

300

300

350

350

390

390

430

470

Cabinet Height

28 7/8"

28 7/8"

28 7/8"

Cabinet Width

17 3/4"

17 3/4"

17 3/4"

Cabinet Length

19 1/4"

19 1/4"

22 3/4"

Supply Outlet Height C.L.

25 3/8"

25 3/8"

25 3/8"

Return Outlet Height C.L.

4 1/2"

4 1/2"

4 1/2"

Flue Outlet Diameter

6"

6"

6"

Flue Outlet Height C.L.

20 3/4"

20 3/4"

20 3/4"

287/8"

173/4"

223/4"

253/8" 4 1/2"

6"

203/4"

28 7/8"

28 7/8"

28 7/8"

17 3/4"

17 3/4"

17 3/4"

26 1/4"

29 3/4"

33 1/4"

25 3/8"

25 3/8"

25 3/8"

4 1/2"

4 1/2"

4 1/2"

6"

6"

6"

20 3/4"

20 3/4"

20 3/4"

Page 4
Image 4
Beckett SL375, SLD375, SL5125, SLD4100, SLD5125, SL7175, SL4100, SL6150 manual Ratings and Data