V-AMPIRE LX1200H/LX210
8.3 MIDI connections
The MIDI standard (Musical Instruments Digital Interface) was developed in the early ’80s to enable different makes of electronic instruments to communicate with each other. Over the years the range of MIDI applications has constantly expanded, and today it is standard practice to network entire recording studios using the MIDI standard.
The heart of such a network is a computer with sequencer software that controls not only all the keyboards but also effects other peripheral devices. In such a studio
The MIDI connectors are
MIDI IN: receives MIDI controller data. The receiving channel can be adjusted in EDIT mode by pressing the A button and then using the arrow buttons.
MIDI OUT/THRU: used for sending data to a computer or any other devices. You can transmit both preset data and parameter changes. If set to MIDI THRU, the
MIDI IN connector (see chapter 2.1, A).
8.3.1 Sending/receiving MIDI Sysex data
Your
To send individual presets to other devices: switch to EDIT mode by pressing both arrow buttons on the transmitting unit simultaneously, activate the MIDI function and briefly tap the MIDI button. The preset data are first filed in the temporary buffer and can be stored in the preset position of your choice using the store function.
9. SPECIFICATIONS
AUDIO INPUTS |
|
Instrument input | 1/4" TS connector, unbalanced |
Input impedance | 1 MΩ |
Max. input level | +9 dBu |
Aux In Stereo | 1/4" TRS stereo connector |
Input impedance | 4,7 kΩ |
Pre DSP Return Line In | 1/4" TS connector, unbalanced |
Input impedance | 2 kΩ |
Max. input level | +9 dBu |
AUDIO OUTPUTS |
|
Analog Line Outputs L/R | 1/4" TS connector, unbalanced |
Output impedance | ca. 680 Ω |
Max. output level | +9 dBu |
Pre DSP Send/Line Out | 1/4" TS connector, unbalanced |
Output impedance | <1 kΩ |
Max. output level | +9 dBu |
Balanced Line Out | XLR, balanced |
Output impedance | 100 Ω |
Max. output level | +14 dBu (Studio); 0 dBu (Live) |
Headphone connector | 1/4" TRS connector, unbalanced |
Max. output level | +15 dBu/100 Ω (+23 dBm) |
MIDI |
|
Type | |
DIGITAL SIGNAL PROCESSING | |
Converter | |
| oversampling |
Dynamics A/D | 104 dB @ Preamp Bypass |
Dynamics D/A | 92 dB |
Sampling rate | 31,250 kHz |
DSP | 100 Mips |
Delay time | max. 1933 ms |
Runtime |
|
(Line In > Line Out) | approx. 5 ms |
DISPLAY |
|
Type | |
AMPLIFIER |
|
Mono power |
|
(1 x 4 Ω) | 120 W (LX1200H only) |
Stereo power |
|
(2 x 8 Ω) | 2 x 60 W |
Sound pressure level | 116 dB @ 1 m |
INTERNAL SPEAKERS (LX210) | |
Type | 2 x 10" BUGERATM |
Impedance | 8 Ω |
Load capacity | 70 W (IEC) / 140 W (DIN) |
POWER SUPPLY |
|
Mains voltage | USA/Canada 120 V~, 60 Hz |
| China 220 V~, 50 Hz |
| Europe/U.K./Australia 230V~,50Hz |
| Japan 100 V~, 50 - 60 Hz |
General export model | 120/230 V~, 50 - 60 Hz |
Power consumption | 200 W max. |
Fuse | for mains voltages 100 - 120 V~: |
| T 5 A H 250 V |
| for mains voltages 200 - 240 V~: |
| T 2.5 A H 250 V |
Mains connection | Standard ICE receptacle |
DIMENSIONS/WEIGHT |
|
LX1200H |
|
Dimensions |
|
(H x W x D) | 226 mm (9") |
| x 612 mm (24") |
| x 266 mm (10 1/2") |
Weight | ca. 14.6 kg (32 1/5 lb) |
LX210 |
|
Dimensions |
|
(H x W x D) | 491 mm (19 1/3") |
| x 611 mm (24") |
| x 265 mm (10 1/2") |
Weight | ca. 21.5 kg (47 1/2 lb) |
BEHRINGER continuously strives to assure the highest quality standards possible. Required modifications may be implemented without prior notice. Technical data and the appearance of the unit may deviate from the above values and/or illustrations.
9. SPECIFICATIONS | 17 |