V-AMPIRE LX1200H/LX210
8.INSTALLATION
8.1Mains voltage
Before connecting the unit to the mains, please make sure that the voltage setting on the unit matches the local voltage! The fuse holder at the AC power connector has 3 triangular markings. Two of these three triangles are aligned with one another. The unit is set to the voltage shown next to these markings and can be switched over by turning the fuse holder by 180°. IMPORTANT: This does not apply to export models designed exclusively for 120 V operation!
+If you set the unit to a different mains voltage, be sure to use a fuse of the correct type and rating. Please refer to chapter 9 “SPECIFICATIONS” for details.
+Blown fuses must be replaced by fuses of the same type and rating! Please refer to chapter 9 “SPECIFICATIONS” for details.
The mains connection is made using the enclosed power cord and a standard IEC receptacle. It meets all of the international safety certification requirements.
+Please make sure that all units have a proper ground connection. For your own safety, never remove or disable the ground conductor from the unit or of the AC power cord. The unit shall always be connected to the mains socket outlet with a protective earthing connection.
8.2 Audio connections
The inputs of your
The DI OUT outputs of your
Fig. 8.1: XLR connectors
Fig. 8.2: 1/4" TS connector
Fig. 8.3: 1/4" TRS connector
Fig. 8.4: Headphone connector
16 | 8. INSTALLATION |