FIELD

TITLE and DATA ENTRIES

EXPLANATION

 

 

 

*82

*83

*84

*85

*86

Non-Alarm Report Codes (Second Digit

Enter 00-15.

First Test Report Time

Enter 00-07the for day (01 = Monday) Enter 00-23for the hour

Enter 00-59for the minutes

Swinger Suppression (partition- specific)

Enter 01-15.

Enter 00 for unlimited reports

Enable Dialer Reports for Panics & Duress (partition-specific)

0 = disable

1 = enable

4208 Module Zone Assignment

0 = other configurations

1 = 10-17 only

This field has ten two-digit entries as follows: Close, Open, Low Battery, Low Battery Restore, AC Loss, AC Restore, Test, Power-up, Cancel, and Program Tamper. Enter the report code 01-15for each type of report.

Enter 00 for no report.

Enter the day and time that the first Test report shall be transmitted. Enter 00 in all locations if the Test report is to be sent immediately upon exiting. Enter 00 in the day location if the report is to be sent at the next occurrence of the time that is set.

This option limits the number of messages (alarms or troubles) sent for a specific zone in an armed period.

Must be 00 for UL installations.

This field has four entries as follows: Zone 95, 96, 99, and Duress. Enable for each partition that the panics and duress reporting is desired.

NOTE: Non-zero report code must be assigned to zone 92 to enable Duress reporting.

Entering 1 allows a single 4208 to be set to zone numbers 10-17, but precludes the use of any other polling loop devices.

Entering 0 allows all other configurations, such as no 4208, more than one 4208, or other polling loop expansion present.

4208 Zone #s available when:

When *86 = 1 4208 DIP switches must be set to:

 

 

 

 

*86 = 1

10-17

Precludes use of any other polling loop expansion

*86 = 0

10-16

17-24

25-32

33-40

41-48

49-56

57-64

With word OFF

sw 2 = ON

sw 3 = ON

sw 4 = ON

sw 5 = OFF

With word ON

sw 2 = OFF

sw 3 = OFF

sw 4 = OFF

sw 5 = ON

*87

*88

*89

Entry Warning (partition-specific)

0 = 3 short beeps

1 = slow continuous beeps

Burglary Alarm Communicator Delay (partition-specific)

0 = no delay

1 = 16-second delay

Restore Report Timing

0 = instant

1 = after bell timeout

2 = when system is disarmed

Select the type of warning for the entry delay period.

Select the delay, if any, for burglary alarm communications.

Must be 0 for UL installations.

Select the time when restore reports are sent after an alarm.

Must be 2 for UL installations.

*90

Secondary Subscriber Account Number (partition-specific)

Enter 00-09; B-F (11-15)

Enter a 3- or 4-digit (depending on report format) secondary subscriber account number. Each number requires a 2-digit entry so as to allow entry of hexadecimal digits (B-F). If a 3-digit account number is to be used, enter data only in the first 3 locations, and enter * in the fourth location.

NOTE: This field must be programmed if a secondary phone number is used (field *34). This account number can be the same as the primary account number.

5-8