Honeywell 3.5 manual Program Modes, Entering and Exiting Programming Mode, S E C T I O N

Models: ZyAIR G-3000 3.5

1 96
Download 96 pages 54.8 Kb
Page 39
Image 39
Programming

S E C T I O N 4

Programming

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

Program Modes

There are two programming modes for the VISTA-40. These are the Data Field Program Mode and the #93 Menu Mode. The Data Field Program Mode is where many system options are programmed. The #93 Menu Mode is an interactive mode that requires a 2-line alpha keypad (6139/6160).

The factory-loaded defaults (97) enable keypad addresses 00-03 only. A keypad set to one of these addresses must be used to program the system initially.

Local keypad programming can be disabled through Compass downloading software. If this is done, Program mode can only be accessed via the downloading software.

Entering and Exiting Programming Mode

Enter Programming mode using either method a or b:

a.Press both the [] and [#] keys at the same time within 30 seconds after power is applied to the control.

b.Enter the Installer Code + [8] + [0] + [0] keys. The factory installer code can be changed once in the Program mode (field 00).

NOTE: The default for the Installer Code is 4140.

Exit the Programming mode by either method a or b:

a.Press [] + [9] + [8]. Exiting by this method prevents the installer code from being used to re- enter Programming mode. Only method “a” can be used to re-enter Programming mode.

b.Press [] + [9] + [9]. Exiting by this method permits the installer code to be being used to re- enter Programming mode.

Data Field Programming Mode

In the Data Field Program Mode you may access any field simply by entering either [] or [#] + the field number:

To write or change information in a field press [] + the field number (03).

To read the information in a field press [#] + the field number (#03).

When the entries for a field are completed, the keypad beeps three times and advances to the next field.

Summary of Data Field Programming Commands

91 Select partition for programming partition-specific fields

92 Display the software revision level of the control panel

93 Enter Menu mode programming

94 Go to next page of fields

99 Go back to previous page of fields or exit Programming Mode with no installer code lockout

98 Exit Programming Mode with Installer Code lockout

Moving Between Programming Levels

The data fields are grouped into three levels (referred to as “pages”). The first page is accessed as soon as Programming Mode is entered.

The second and third pages of data fields are indicated at the keypad by a 1 and 2, respectively, in front of the 2-digit field address. “ALT PROGRAM MODE” is displayed along with a “100” or “200,” indicating which page of program fields is accessed.

To access the next level of programming fields, perform the following steps:

Step Action

1Press 94.

2Press [7] + [XX], where XX = the last two digits of the program field, and make the desired entry.

NOTES:

Press 94 to move to 2nd page, (fields 101 - 176); press 99 to move back to 1st page.

Press 94 to move to 3rd page (fields 200 - 221); press 99 to move back to 2nd page

4-1

Page 39
Image 39
Honeywell 3.5 manual Program Modes, Entering and Exiting Programming Mode, Data Field Programming Mode, S E C T I O N