Honeywell ZyAIR G-3000, 3.5 VISTA-40Installation and Setup Guide, Field, TITLE and DATA ENTRIES

Models: ZyAIR G-3000 3.5

1 96
Download 96 pages 54.8 Kb
Page 48
Image 48
*12

VISTA-40 Installation and Setup Guide

FIELD

TITLE and DATA ENTRIES

EXPLANATION

 

 

 

*12

*13

Exit Delay #2 (partition-specific)

Enter 03-15multiplied by 15 seconds. 00 = no delay.

Alarm Sounder Duration (partition-specific)

Exit Delay #2 is used for a secondary door requiring a longer delay than those assigned to Exit Delay #1.

NOTE: The delay may not exceed 60 seconds for UL installations.

Defines the length of time the Bell Output and the keypad’s sounder will sound for all audible alarms.

*14

*15

Enter 01-15multiplied by 2 minutes. 00 = no timeout.

Zone 9 Fast/Slow Response

0 = slow 350ms

1 = fast 10ms

Keyswitch Assignment

Enter 1-2partition keyswitch is being used. Enter 0 if the keyswitch is not used.

Must be minimum 16 minutes for UL Commercial Burglary installations.

Select the response time for devices connected to zone 9.

The keyswitch requires the use of zone 7 wired loop (zone 7 is no longer available as protection zone). The fire and panic alarm voltage triggers (J7) automatically become ARMING and READY status outputs for the Keyswitch LEDs.

Openings/closing report as user “0” if enabled in field *40.

*16

*17

*19

*20

Confirmation of Arming Ding (partition-specific)

0 = disable

1 = enable

AC Loss Keypad Sounding

0 = disable

1 = enable

Randomize AC Loss Report

0 = disable

1 = enable

VIP Module Phone Code

￿1-9= first digit of access code

or # = second digit of access code (enter # +11 for “”, or # +12 for “#”)

To disable enter 00 for the 1st digit

If enabled, produces ½-second external alarm sounding (“ding”) at the end of exit delay (or after kissoff from the central station, if sending closing reports).

Must be 1 for UL installations.

If enabled, sounding at the keypad (rapid beeping) occurs when AC power is lost (sounding occurs about 2 minutes after actual AC loss).

If enabled, randomizes AC loss reporting between 10 and 40 min. after an actual AC loss.

If disabled, AC loss reporting about 2 minutes after actual AC loss.

Selecting this option helps prevent an overload of AC loss messages at the central station during a community blackout.

If a 4285/4286 Voice Module is being used, enter the 2-digit phone code used to access the system.

Must be disabled for UL installations.

*21

Prevent Fire Timeout

If enabled, there is no timeout of the alarm sounder duration for all fire

0

= disable (timeout)

zones, regardless of partition, so that fire sounding continues until the

1

= enable (no timeout)

system is reset.

 

 

If disabled, (timeout) the normal burglary sounder duration (field 13)

 

 

applies to fire alarms.

 

 

 

*22

*23

Keypad Panic Enables (partition- specific)

0 = disable

1 = enable

Multiple Alarms (partition- specific)

0 = disable

1 = enable

If enabled, the keypad panics (zones 995, 996, and 999) may be used in this partition. There are 3 entries in this field, one for each panic.

If enabled, allows more than one alarm sounding for a given zone during an armed period.

NOTE: that multiple alarm soundings will not occur more frequently than allowed by the programmed alarm sounder duration. This has no impact on the number of communication messages transmitted.

Must be 1 for UL installations.

5-2

Page 48