Image 58
2*02

VISTA-40 Installation and Setup Guide

FIELD

TITLE and DATA ENTRIES

EXPLANATION

 

 

 

 

2*02

 

Daylight Saving Time Start/End

 

 

Weekend

 

 

 

 

 

0

= disable

 

 

1

= enable

 

 

 

 

 

2*17

Number of Codes per Partition

Enter 01-69

 

 

2*18

 

Enable GOTO for this Partition

 

 

(partition-specific)

 

 

 

 

 

0

= disable

 

 

1

= enable

 

 

 

 

 

 

 

Use Partition Descriptor

 

2*19

 

 

0

= disable

 

 

 

 

1

= enable

 

 

 

 

 

 

 

Enable J7 Triggers for Partition

 

2*20

 

 

 

(partition-specific)

 

 

 

 

 

0

= disable

 

 

1

= enable

 

 

 

 

 

 

 

Supervision Pulses for LRR

 

2*21

 

 

0

= disable

 

 

 

 

1

= enable

 

 

 

 

 

Enter the start and end weekends for daylight saving time as follows: 1=first; 2=second; 3=third; 4=fourth; 5=last; 6=next to last; 7=third from last. Standard setting for U.S. is 1,5.

This field has two 2-digit entries. Enter the number user codes for each partition. The total number of user codes cannot exceed 70 for the system. Enter 01 for an unused partition.

NOTE: The installer code is automatically assigned to each partition regardless of whether that partition has been enabled.

If enabled, this partition can be accessed from another partition’s keypad using the GOTO command.

If enabled, the normal keypad display will include a partition number and four-digit descriptor.

If enabled, the J7 triggers function for this partition.

There are three entries in this field as follows: Fire, Burglary/Audible Panic, Silent Panic/Duress.

If enabled, causes the control to send periodic short pulses on the J7 radio triggers to the LRR. The LRR uses these pulses to determine that its connection to the control is still intact.

Must be 1 for UL installations.