Installing a Remote Keyswitch

VISTA-40 Installation and Setup Guide

J7 CONNECTOR

 

 

 

 

 

 

 

4142TR

 

 

 

 

 

 

 

CABLE

 

 

 

 

GROUND START

GRAY (GROUND)

 

 

675

 

 

 

 

 

TRIGGER

 

YELLOW (OUT 1)

 

GROUND

BLUE

 

WHITE (GROUND)

 

START

 

 

 

 

 

 

 

 

 

RED (OUT 2)

 

MODULE

 

 

TO AUX. POWER

 

 

 

 

 

 

 

 

 

 

 

BLACK

GREEN (GROUND)

(CUT ORANGE

TERM. 7

 

 

 

 

 

 

 

 

JUMPER)

 

 

TO AUX. POWER

BROWN (OUT 3)

 

 

 

 

VIOLET

BLUE (GROUND)

 

 

 

 

TERM. 6

BROWN

 

GREEN

 

 

 

(50mA CURRENT DRAW)

BLACK (OUT 4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IF USED:

 

 

 

 

 

 

 

1. OUT 1 IS NO LONGER

 

TO

TO

 

 

USABLE FOR SMOKE DETECTOR RESET

TELCO

EARTH

 

 

(SEE FIELD 1*46).

 

RING

GROUND

2. OUT 2, 3, 4 CAN STILL BE

 

USED TO PROVIDE ALARM STATUS INDICATIONS OR TO OPERATE A KEYSWITCH (SEE FIELD *15).

3. THE 675 IS NOT UL LISTED.

N/U

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

Figure 3-23: Ground Start Module Connections

Installing a Remote Keyswitch

A UL-Listed remote keyswitch, such as the 4146, can be used for remote arming/disarming of the burglary portion of the system and for silencing alarms. The keyswitch can operate in only one particular partition.

The keyswitch is wired across zone 7. This zone is no longer available as a protection zone. Be sure to program Zone 7 with a response type (e.g., type 10).

Operation

A momentary short across zone 7 arms the partition in the AWAY mode, and a short held for more than 3 seconds arms the partition in STAY mode. A subsequent short disarms the partition.

The keyswitch LEDs indicate the partition’s status (see table below).

A momentary short across Zone 7 silences alarm bell and keypad sounds, and disarms the system if it was armed. A subsequent short across Zone 7 clears the alarm memory indication and resets 2- wire smoke and glassbreak detectors (if used).

LED Indications

Green

Red

Indication

 

On

Off

Disarmed & Ready

 

Off

Off

Disarmed & Not Ready

 

Off

On Steady

Armed Away

 

Off

Slow Flash

Armed Stay

 

Off

Rapid Flash

Alarm Memory

 

 

 

 

 

 

Keyswitch Tamper Operation

The tamper switch need not be used for fire or UL Household Burglary installations. For UL Commercial Burglary installations, the tamper switch must be wired to a zone (zone 6 in Figure 3-24).

Program that zone for Day Trouble/Night Alarm (response type 5). When the keyswitch is removed from the wall, the tamper switch opens, causing an alarm or trouble on the zone. This also causes the control to disable keyswitch operation until the tamper is restored and the associated partition is disarmed.

Wiring for the Remote Keyswitch

To install the 4146 keyswitch, perform the following steps:

Step Action

1Connect the 4146 to the panel as shown in Figure 3-24.

2If you are using the tamper, make sure it is connected to a zone.

The keyswitch reports as user 0, if Open/Close reporting is enabled in field 40.

3-18

Page 28
Image 28
Honeywell ZyAIR G-3000 Installing a Remote Keyswitch, VISTA-40Installation and Setup Guide, 3-18, Operation, Step Action