Zone Number Designations

VISTA-40 Installation and Setup Guide

Zone Number Designations

The VISTA-40 supports up to 64 zones of hardwire, polling loop and/or wireless protection, distributed among up to 2 partitions. The following table lists the zone numbers and the types of sensors that can be used with each, and some alternate functions of the zones.

Zone

Function

Zone Index

The zones are designated as follows:

ZONE #

ZONE
ACTUAL ZONE
RANGE
FUNCTION

 

01 – 64

Protection

As indicated

 

zones

 

1

2-wire Smoke Detectors (if used)

5

Audio Alarm Verification (if used)

7Keyswitch (if used)

8Latching-Type Glassbreak Detectors (if used)

1-9 Traditional Hardwired Zones

1-64 5800 Series Wireless Devices

10-64 Polling Loop Devices

95+ 1 Panic

96# + 3 Panic

99

+ # Panic

70, 88, 89,

System

90, 91, &

Supervisory

97

Zones

 

 

70:Bell Supervision

88:2nd Wireless Receiver – not receiving signals

89:2nd Wireless Receiver – not talking to control

90:1st Wireless Receiver – not receiving signals

91:1st Wireless Receiver – not talking to control

97:Polling Loop (short circuit)

Zone Defaults

Zone #

Zone Type

01

09

Zone #

70

Zone Type

00

92, 95, 96,

Duress and

& 99

Keypad Panics

92:Duress

95:1 + panic (A key)

96:3 + # panic (C key)

99: + # panic (B key)

02

03

03

03

04

03

05

03

06

03

07

03

08

03

0903

10–6400

87

88

90

91

92*

95

96

97

99

00

00

00

00

N/A

00

00

05

06

Supervisory zones should be given a response type of 05 (Trouble by Day, Alarm by Night).

NOTES: *Zone 92 is the Duress zone. Programming of the zone response type is not applicable. This zone requires only the report code programming.

Communication Defaults

*45

PRIMARY FORMAT

[1] ADEMCO Contact ID

*51

DUAL REPORTING

 

[0] no

 

*46

LOW SPEED FORMAT (Prim) [0] ADEMCO Low Speed

*52

STANDARD/EXPANDED REPORT FOR PRIMARY

*47

SECONDARY FORMAT

[1] ADEMCO Contact ID

 

[0]

[0]

[0]

[0]

[0]

[0]

standard

*48

LOW SPEED FORMAT (Sec.)

[0] ADEMCO Low Speed

 

Alarm

Rstr

Bypass

Trbl

Opn/Cls Low Bat

 

*49

CHECKSUM VERIFICATION [0]

[0]

*53

STANDARD/EXPANDED REPORT FOR SECONDARY

 

No checksum

Primary

Secondary

 

[0]

[0]

[0]

[0]

[0]

[0]

standard

*50

SESCOA/RADIONICS SEL.

[0] Radionics

 

Alarm

Rstr

Bypass

Trbl

Opn/Cls Low Bat

 

4-4

Page 42
Image 42
Honeywell ZyAIR G-3000 Zone Number Designations, VISTA-40Installation and Setup Guide, Zone Index, Zone Defaults, Zone #