VISTA-40 Installation and Setup Guide

Entry Errors

If an address is improperly entered, the keypad displays “FC.”

If a program entry is improperly entered (for example, a larger number than is permitted), the keypad display will go blank.

In either of the above cases, simply re-enter [] + the correct field number and then enter the correct data.

Programming System-Wide Data Fields

Values for some programming fields are system-wide (global), and some can be different for each partition (partition-specific).

The partition-specific programming fields are automatically skipped when programming the global fields. If the system has only 1 partition, the partition-specific fields are not automatically skipped.

To program system-wide data fields, perform the following steps:

Step Action

1Enter Program Mode: Installer Code + 8 0 0. The following display appears:

Program Mode

Fill # View – 00

2If the control has not been programmed before, enter 97 to load factory defaults.

3Press [] and enter the first field number to be programmed (for example, 00, Installers Code). Make the desired entry. When the field is complete, the keypad beeps three times and advances to the next field. If you do not want to change the next field, press [] and enter the next field number to be programmed.

 

 

 

First Page of fields

 

 

 

 

 

 

 

 

 

 

 

(00 - 90)

 

 

 

To change to the next page of fields, press 94.

 

To return to the previous page of fields, press

 

99.

 

 

4

Press 99 or 98 to exit Program Mode.

NOTE: If the number of digits that you enter in a data field is fewer than the maximum permitted (for example, a phone number), the keypad displays the last entry and waits. To proceed, enter [] + the next data field you wish to program.

Programming Partition-Specific Data Fields

To program partition-specific data fields once in Program Mode, do the following:

Step Action

1Enter Program Mode: Installer Code + 8 0 0.

2Press 91, which will prompt you for the partition number desired.

3Enter a partition-specific field number (e.g., 09) to begin programming.

When the first field’s entry is completed, the next partition-specific field is automatically displayed. When all partition-specific fields are programmed, the system returns to the global programming fields (page 1 fields).

4Repeat this procedure for the other partition.

NOTE: To return to the global program fields before finishing all fields, enter any global field number.

Programming Partition-Specific Fields
Press 91 to select a partition.

p

Enter the partition to be programmed.

p

Enter a partition-specific field number and make
entry.

p

Enter any global field number to return to the global

fields at any time.

#93 Menu Mode Programming

The #93 Menu Mode is an interactive mode through which much of the system’s programming is done. In this mode, there are “question and answer” prompts that can be accessed once Data Field Program Mode has been entered. These prompts require a 2-line alpha keypad (6139/6160).

After programming all system-related programming fields in the usual way, press #93 while still in programming mode to display the first choice of the menu-driven programming functions. Press 0 (NO) or 1 (YES) in response to the displayed menu selection. Pressing 0 will display the next choice in sequence.

4-2