Section 9 – User Access Codes

Section 9 – User Access Codes

Adding a Master, Manager, or Operator Code

During user code entry, normal key depressions at other keypads in a partition are ignored. However, panic key depression causes an alarm and terminates user entry.

Enter Installer Code+ [8] + new user no. (02-69) + new user’s code

Or Master or Manager Code, but the code must be a higher level of authority than the code being changed (e.g., a Manager Code can add an Operator-level Code, but cannot add a Master or another Manager Code). Keypad prompts for the authority level for this user.

PROMPTEXPLANATION

User Number = 03 Enter Auth. Level

Enter the level number as follows:

1 = Master

2 = Manager

3 = Operator Level A

4 = Operator Level B

5 = Operator Level C

6 = Duress

Open/Close Rep.? 0 = NO , 1 = YES

RF Button ? 0=NO , 1=YES

Enter Button ZN # (01-63)

Multi-Access ?

0 = NO , 1 = YES

Global Arm ?

0 = NO , 1 = YES

Part. 2 – SHOP ? 0 = NO , 1 = YES

Part. 1 A06WHSE User 03 Auth=3G.

Keypad then prompts for Open/Close reporting option for this user.

Press 0 (NO) or 1 (YES), depending on whether or not arming/disarming by this user will trigger Opening and Closing reports. This prompt appears only if the Installer Code is used to add a user.

If a 5800 Series button transmitter has been enabled for arming/disarming functions, and is not assigned to a user, this prompt appears. Press 0 (NO) or 1 (YES).

If you answered “yes” to the RF button question, the zone number for the button is requested. Enter any one of the zone numbers assigned to the button transmitter as AWAY, STAY, or DISARM. The system then assigns all buttons of the transmitter to this user number.

Press 0 (NO) if the user is to have access to this partition only. Press 1 (YES) if the user is to have access to more than one partition. If NO, the program exits this mode. If YES, the keypad prompts for the Global Arm option for this user.

Press 0 (NO) or 1 (YES), depending on whether this user will be allowed to arm more than one partition via Global Arm prompts.

The keypad now prompts for the user’s access to the next partition.

Press 0 (NO) or 1 (YES), depending on whether this user will have access to the displayed partition number. If NO, the keypad displays this prompt for the next partition number in sequence.

If YES, the keypad prompts for the following:

User’s authority level in the displayed partition (see Authority Level prompt above).

Open/Close option for this user in the displayed partition (see Open/Close prompt above).

Global Arm option for this user in the displayed partition (see Global Arm prompt above).

When all partitions have been displayed, the keypad will scroll through all partitions to which access has been assigned, and will display the user number, authority level, open/close and global arm options that were programmed for each partition to which the user was granted access. See next prompt.

Note that the “G” following the authority level indicates that the global arm feature is enabled for this user in the displayed partition, and that the period at the end of the second line indicates Open/Close reporting is enabled for this user in the displayed partition. The “6” indicates the partition from which the user may be changed or deleted.

8-3

Page 67
Image 67
Honeywell 3.5, ZyAIR G-3000 manual Adding a Master, Manager, or Operator Code, User Access Codes, Promptexplanation