Primary Phone Number

VISTA-40 Installation and Setup Guide

FIELD

TITLE and DATA ENTRIES

EXPLANATION

 

 

 

*33

Primary Phone Number

Enter 0-9; #11 for *, #12 for #, #13 for a 2-

 

 

second pause.

Enter the primary central station phone number, up to 17 digits. This is the phone number the control will use to transmit Alarm and status messages to the central station. Do not fill unused spaces.

NOTE: Backup reporting is automatic only if a secondary phone number is entered.

*34

Secondary Phone Number

Enter 0-9; #11 for *, #12 for #, #13 for a 2-

 

 

second pause.

Enter the secondary phone number, up to 17 digits. The secondary phone number is used if communication on the primary number is unsuccessful, or if split/dual reporting is desired. Do not fill unused spaces.

NOTE: If this field is programmed, a secondary subscriber account number (field *90) must also be programmed.

*35

*36

Download Phone Number

Enter 0-9; #11 for *, #12 for #, #13 for a 2- second pause.

Download ID Number

Make entries as 2-digit numbers as follows: 00=0 01=1 02=2 03=3 04=4 05=5 06=6 07=7 08=8 09=9 10=A 11=B 12=C 13=D 14=E 15=F

Enter the downloading phone number, up to 17 digits. Do not fill unused spaces.

NOTE: This field is applicable only if downloading is utilized.

Enter eight digits.

NOTE: This field is applicable only if downloading is utilized.

*37

Download Command Enables

Enabling a function means that you are able to perform that function via

0

= disable

the Compass Downloading software.

1

= enable

Functions are as follows: Dialer Shutdown; System Shutdown; Not Used;

 

 

Remote Bypass; Remote Disarm; Remote Arm; Upload Program;

 

 

Download Program.

 

 

For UL installations, all entries must be 0.

 

 

 

*38

*39

*40

*41

*42

Prevent Zone XX Bypass (partition-specific)

Enter a zone number (01-64).

Enter 00 if all zones can be bypassed.

Enable Open/Close Report for Installer Code (partition-specific)

0 = disable

1 = enable

Enable Open/Close report for Keyswitch

0 = disable

1 = enable

Normally Closed or EOLR (Zones 2-8)

0 = disable

1 = enable

Dial Tone Pause

Enter the wait time for dial tone detection: 0 = 5 seconds; 1 = 11 seconds; 2 = 30 seconds.

Enter two digits for zone that cannot be bypassed by the user.

NOTES:

The actions manual bypass, and STAY/INSTANT arming modes cannot bypass any zone programmed in this field.

If enabled, whenever the Installer Code is used to arm or disarm the partition, an open/close report is sent to the central station.

If enabled, whenever the keyswitch is used to arm or disarm the partition, an open/close report is sent to the central station.

If disabled, end-of-line resistors must be used on zones 2-8.

If enabled end-of-line resistors cannot be used and only normally closed devices must be used.

Must be 0 for UL installations.

Enter the time the system waits for dial tone before dialing. Applies if true dial tone is not selected in field *43.

Must be 0 for UL installations.