Section 5 – Data Field Descriptions

Section 5 – Data Field Descriptions

FIELD

TITLE and DATA ENTRIES

EXPLANATION

 

 

 

*24

*25

*26

*27

*28

*29

Ignore Expansion Zone Tamper

0 = disable (tamper detection)

1 = enable (no tamper detection)

Burglary Trigger for Response Type 8

0 = disable

1 = enable

Intelligent Test Report

0 = disable

1 = enable

Test Report Interval

Enter 001-199for the test report interval in hours.

Enter 000 for test reporting.

Power-Up in Previous State

0 = disable

1 = enable

Quick Arm (partition-specific)

0 = disable

1 = enable

If disabled, the system monitors the tampers on expansion zones.

NOTE: Only applicable to certain polling loop sensors with tamper switches or 5800 Series transmitters.

Must be 0 for UL installations.

If enabled, allows triggering of Output 3 (pin 7) of the J7 header to include zone response type 8 (24-hr. auxiliary).

If enabled, no test report is sent if any other type of report was sent since the last test report.

If disabled, test reports are sent at the set intervals, regardless of whether or not any other report has been sent.

Must be 0 for UL applications.

If a test report is desired, enter a test code in field *81 and *82. Set first test report time in field *83.

Maximum Test report interval is 024 for UL installations.

If enabled, the system, upon power-up, reverts to its status prior to a complete power loss.

If disabled, the system always powers up in a disarmed state.

NOTE: Neither authority level 0 nor 5 can be used to disarm the system if the control powers up armed.

Must be 1 for UL applications.

If enabled, allows arming of the burglary system in AWAY, STAY, INSTANT, or MAXIMUM mode by using the [#] key instead of the user code.

NOTES:

When armed, the system reports closing as User 0 if Open/Close reporting for User #2 (typically a Master level user) was enabled for a given partition.

If Quick Arm is used, the Installer Code and Authority Level 5 codes cannot disarm the system.

*30

TouchTone or Rotary Dial
Select the dialing method for the system

0

= disable

 

 

 

 

1

= enable

 

If you select TouchTone, make sure the subscriber has requested and is paying for TouchTone service. Note that whether or not TouchTone dialing for call placement is permitted, communication by the use of DTMF signaling (ADEMCO High Speed) will still take place. See field 1*33 for TouchTone w/Rotary backup

*31

*32

PABX Access Code

Enter 00-09; B-F (11-15)

Primary Subscriber’s Account Number (partition-specific)

Enter 00-09; B-F (11-15)

This field is used to enter up to four 2-digit numbers representing the prefix needed to obtain an outside telco line. If not required, enter nothing and proceed to next field.

Enter a 3- or 4-digit (depending on report format) primary subscriber account number. Each number requires a 2-digit entry so as to allow entry of hexadecimal digits (B-F). If a 3-digit account number is to be used, enter data only in the first 3 locations, and enter * in the fourth location.

5-3

Page 49
Image 49
Honeywell 3.5 manual 24 25 26, Data Field Descriptions, TITLE and DATA ENTRIES, Explanation, Ignore Expansion Zone Tamper