Changing a Master, Manager, or Operator Code

VISTA-40 Installation and Setup Guide

Changing a Master, Manager, or Operator Code

Enter Installer Code*+ [8] + new user no. (02-69) + new user’s code

*Or Master or Manager Code, but the code must be a higher level of authority than the code being changed (e.g. a Manager Code can add an Operator-level Code, but cannot add a Master or another Manager Code).

PROMPTEXPLANATION

User Number = 03

NEW USER?

The system detects that the user number is already assigned, and prompts if this is a new user.

Press 0 (NO).

The system then confirms that the change is allowed based on authorization level.

Adding an RF Key to an Existing User

To add an RF key to an existing user, or to change a user’s global arm option, first delete that user’s code, then re-add the user code as described in the “Adding a Master, Manager, or Operator Code” paragraph.

Deleting a Master, Manager, or Operator Code

Enter your code*+ [8] + new user no. (02-69) + your code again

*Or Master or Manager Code, but the code must be a higher level of authority than the code being changed (e.g. a Manager Code can add an Operator-level Code, but cannot add a Master or another Manager Code).

PROMPTEXPLANATION

OK TO DELETE 03?

0=NO 1=YES

The system prompts to confirm that you want to delete this user. Press 0 (NO) or 1 (YES).

If you answer “yes,” that user’s code is removed from all partitions to which it was assigned, and all authorization levels and other information about that user are deleted. Note: A user can be deleted only by a user with a higher authority level. A user cannot delete himself.

A user code can be deleted only from the partition through which it was entered. If an attempt is made to delete from another partition, the message “User [XX] Not Deleted” is displayed.

Exiting the User Edit Mode

Press either [7] or [#], or don’t press any key for 10 seconds.

8-4

Page 68
Image 68
Honeywell ZyAIR G-3000, 3.5 manual Changing a Master, Manager, or Operator Code, Adding an RF Key to an Existing User