A P P E N D I X B

A P P E N D I X B

Summary of System Commands

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

User Code Commands

Programming Commands

Event Logging Commands

Add A User Code = User Code + 8 + New User Number + New User’s Code Change a Code = User Code + 8 + User Number + New User’s Code

Delete a User’s Code = Your User Code + 8 + User Number to Be Deleted + Your Code Again

View User Capability = User’s Code + [] + []

Set Real-Time Clock (Installer, Master Only) = Code + [#] + 63

Site Initiated Download = User Code + [#] + 1.

Direct-Wire Download Enable = User Code + [#] + 5.

Enter Program Mode = Installer Code + 800.

Enter Interactive Program Mode = Installer Code + 800 + [#] + 93

Exit Program Mode = 99 or 98.

Event Log Display = Code + [#] + 60 (Installer or Master Only)

Event Log Print = Code + [#] + 61 (Installer or Master Only)

Clear Event Log = Code + [#] + 62 (Installer or Master Only)

Wireless System Commands

House ID Sniffer Mode = Code + [#] + 2 (Installer Only) Transmitter ID Test = Code + [#] + 3 (Installer Only) Go/No Go Test = Code + 5 (Test Key)

Additional Commands

Partition GOTO

GOTO Home Partition

Panics

View Downloaded Messages

User Code + [] + Partition Number 0-2.

User Code + [] + 0.

[] + 1 or A Key (Zone 95).

[] + [#] or B Key (Zone 99).

[#]+ 3 or C Key (Zone 96). Press 0 for 5 Seconds.

Relay Device Control Commands

Access Control Commands

Display All Zone Descriptors

Press [] for 5 Seconds.

Display User Self Help

Hold Any Key for 5 Seconds.

Activate Relay Device as Programmed = User Code + [#] + 71.

Activate Relay Device as Programmed = User Code + [#] + 72.

Activate Relay Device Manually = User Code + [#] + 70.

Activate Access Relay for Current Partition = User Code + 0.

B-1