If you mount the VIP Module inside the

Section 3 - Installing the Control

To install the VIP module, perform the following steps:

Step Action

1

Mount the module in the control cabinet if

 

space is available or, if this is not possible, on

 

the side of the cabinet or adjacent to it.

Step Action

4Connect the module to the phone line as shown below. See Figure 3-27.

If you mount the VIP Module inside the

control cabinet, attach it to the cabinet’s

interior surface with 2-faced adhesive tape.

You may leave the module’s cover off if it is

mounted within the cabinet.

If you mount the module outside the

cabinet, use the screw holes at the rear to

mount horizontally or vertically (2-faced

adhesive tape may be used, if preferred).

If you mount the module outside thecontrol cabinet’s door.￿

4285/4286 Terminal

1.Phone In (Tip)

2.Phone In (Ring)

3.Phone Out (Tip)

4.Phone Out (Ring)

5.No Connection

6.Audio Out 1

7.Audio Out 1

Connects to direct connect cord:

green wire

red wire

brown wire

gray wire

Speaker

Speaker

2

Affix the 4285/4286 connections label

 

(supplied separately) to the inside of the VIP

 

Module’s cover, if the cover is used.

 

Otherwise, affix the label to the inside of the

 

control cabinet’s door.

3

Make 12V (+) and (–) and data-in and data-

 

out connections from the VIP Module to the

 

control, using the connector cable supplied

 

with the VIP Module. These are the same

 

connections as for remote keypads.

Supported by the 4286 only

Use an RJ31X Jack with the phone cable supplied with the control to make connections to the VIP module. Make connections exactly as shown in Figure 3-27. This is essential, even if the system is not connected to a central station. The 4285/4286 will not function if this is not done.

If touch-tones are not present following phone access to the security system via an on- premises phone, try reversing the pair of wires connected to terminals 3 and 4 on the 4285/4286.

If the phone plug is disconnected from the control, the premise’s phones will not operate.

SPEAKER NOTE: IF CONNECTING SINGLE SPEAKER, USE 8-ohm SPEAKER ONLY.

 

 

 

 

 

IF CONNECTING 2 SPEAKERS, USE 4-ohm or 8-ohm SPEAKERS

 

 

 

 

 

AND CONNECT IN SERIES.

 

 

 

INCOMING TELCO LINE

 

 

 

 

 

 

 

4286 VIP MODULE

67

SEE SPEAKER NOTE

TIP

RING

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

 

 

4 5

GREY

 

RJ31X

TIP

 

4286 DEVICE

SPEAKER

3

BROWN

 

RING

PREMISES

ADDRESS IS

VOLUME

2

 

 

JACK

FACTORY SET

CONTROL

1

GREEN

RED

 

 

 

ANSWERING

TO “4”

 

 

CALLER ID

 

MACHINE AND

 

 

NO

 

 

 

 

PHONES

 

 

 

 

 

UNIT

 

 

 

 

 

CONNECTION

KEYED

 

 

 

 

ANSWERING

 

 

 

HEADER

 

EARTH

 

 

 

MACHINE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GROUND

 

 

 

 

YELLOW

GREEN

 

TO CONTROL PANEL

TIP RING TIP RING

 

 

 

 

 

KEYPAD CONNECTIONS HANDSET INCOMING

 

 

 

 

4500

 

 

 

TELCO LINE

 

 

 

 

 

 

YELLOW

 

 

 

 

 

 

THERMOSTAT

 

 

 

 

 

 

 

 

NO CONNECTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

BLACK

 

 

 

 

 

 

 

 

 

GREEN

 

 

 

 

 

 

IMPORTANT NOTE FOR EXISTING INSTALLATIONS: EXISTING WIRES CONNECTED TO THE “HANDSET” TERMINALS ON CONTROL MUST BE MOVED FROM THERE TO TERMINALS 3 AND 4 ON THE 4286.

THIS DEVICE COMPLIES WITH FCC RULES, PART 68 FCC REGISTRATION No. AC3USA-74659-KX-N RINGER EQUIVALENCE: 1.0B

U.S. PATENT No. 4791658

FOR COMPLETE INFORMATION, SEE INSTALLATION

INSTRUCTIONS N6431-3 ACCOMPANYING 4286 VIP MODULE

4286_wiring-002-V1

Figure 3-27: VIP Module Connections

3-21

Page 31
Image 31
Honeywell 3.5 Installing the Control, 3-21, Step Action, If you mount the VIP Module inside the, control cabinet’s door