53X32 DIGITAL MIXER Preliminary User Manual
7.5.5Setup Screen: DCA TabThe setup screen’s DCA tab allows setup of the console’s digitally controlled amplifiers grouping feature, also known as DCAs.
A DCA group is a grouping function, made possible by the console’s digital operation, where individual input channels can be grouped together and controlled with a single output fader on the
a DCA group does not combine the different input channels into a common
LCD screens.
To adjust the various DCA settings, perform the following steps:
1.Adjust the 1st encoder to select which of the eight DCA groups you wish to edit.
2.Tap the 1st encoder to enter the “edit” page for the currently highlighted DCA, where its color, icon, and name can be adjusted.
On the DCA edit page, perform the following steps:
1.Adjust the 1st encoder to set the color for the currently selected DCA group. This selected color will be shown on the console in two ways:
•The selected color will be shown in the LCD screen above the selected DCA’s output fader, on the right hand side of the console. For example, if DCA#5 is assigned the color red, the LCD screen above output fader #5 will illuminate in red.
•Any input channels assigned to that DCA will display their respective LCD screens in the DCA group’s assigned color. These input channels thus have a strong visual reminder of what DCA output fader they are all controlled by.
2.Adjust the 2nd encoder to select the graphical icon for the DCA. A large variety if
3.Adjust the 3rd encoder to select a name from a list of common preset names (snippets), for the currently selected DCA groups.
4.Tap the 3rd encoder to assign the currently highlighted preset text (snippet) to the DCA.
5.Adjust the 4th encoder to move the text entry cursor forward/backward, in the DCA’s name field.
6.Tap the 4th encoder to issue a “backspace” command, deleting the currently highlighted character.
7.Adjust the 5th encoder to select a letter, number, or symbol to enter into the DCA’s name field
8.Tap the 5th encoder to insert the currently highlighted letter, number, or symbol into the DCA's name field.
9.Adjust the 6th encoder to select whether the text entry choices offer numbers, letters, or symbols.
10.Tap the 6th encoder to exit the DCA editing page, and save the current parameters to the DCA.