Beko CCB 5140 XA user manual 5Maintenance, Cartridge type oil filters, Cleaning the hood

Models: CCB 5140 XA

1 16
Download 16 pages 21.19 Kb
Page 10
Image 10
5Maintenance

5Maintenance

Note:

Service your hood periodically! C Service is also required to prevent

burning of oil filter besides obtaining better performance and better effi- ciency.

5.1 Cartridge type oil filters

Cleaning

Cartridge type filters shall be cleaned every two months in normal use. It may be cleaned in a dishwasher or by hand using mild detergent or liquid soap.

Cartridge type filters are easily removed, one at a time, by pushing it slightly towards the rear of the hood while pulling downwards (fig. 5).

5.3 Cleaning the hood

•• Hood must only be cleaned when it is unplugged from mains outlet or when the fuse is switched off!

•• Hood must not be cleaned with a vapor cleaner as it is not ensured that it would operate safely afterwards due to water vapor.

Outer surfaces of the hood must be cleaned with a mild cleaning agent (e.g. dish soap). Do not use strong cleaning agents, abrasive agents or sharp objects.

Stainless steel surfaces shall be cleaned with a commercially available stainless steel cleaning agent and a soft, non-abrasive sponge or cloth. In order to prevent scratches, wiping action shall be performed on the direction of surface structure while you are cleaning the stainless steel surfaces.

Figure 5

Note:

C There could be a possible fire hazard if the filters are not replaced accor- ding to these instructions

5.2.Carbon filters (optional):

In the recirculation mode the carbon filters absorb smell and odors.

Carbon filters cannot be washed or regenerated. They must be replaced every 2 months or more frequently if the hood is used consistently.

Replacement:

•• Dismantle the ducting support by pulling the two knobs (A) (fig. 1) simultaneously to remove the ducting grill.

•• Replace the carbon filter.

•• Close the ducting grill.

5.4.Replacement of lamps

Illumination is made with 2 pieces of 28 W lamps. If the lamps do not work, open the suction grille and check that they are properly fitted. If the lamps have burned out they must be replaced with new ones at equivalent voltage and power.

Replacement:

28 W lamp (fig. 6): unscrew the burned out lamp and fit the new one.

When replacing, ensure that the pins are correctly inserted into the lamp holders.

Install the suction grille back.

Figure 6