Beko CTB 6250 XA, CTB 9250 XA user manual 5Maintenance, Grease Filters

Models: CTB 9250 XA CTB 6250 XA

1 16
Download 16 pages 27.38 Kb
Page 10
Image 10
5Maintenance

5Maintenance

5.1 Grease Filters

5.1.1Cleaning Metal Self- Supporting Grease Filters

The filters must be cleaned every 2 months, or more frequently in case of particularly heavy use of the hood. Filters can be washed in a dishwasher.

Pull out the sliding suction panel.

Remove the filters one by one, after having dis- connected the relative fastening elements.

Wash the filters, taking care not to bend them. Let them get dry before refitting them. (The co- lour of the filter surface may change throughout the time but this has no influence to the filter efficiency).

When refitting the filters, make sure that the handle is visible on the outside.

Close the sliding suction panel.

5.2Charcoal filter (Recycling version) 5.2.1 Replacing Charcoal Filters

A Warning: Turn the lights off and wait until the lamps cool down before you change the odour filter.

These filters are not washable and cannot be regenerated, and must be replaced approxima- tely every four months or more frequently by particularly heavy use.

Pull out the sliding suction panel.

Remove the grease filters.

Remove the saturated carbon filter by releasing the fixing hooks

Fit the new filter by hooking it into its seating.

Replace the grease filters.

Close the sliding suction panel.

10 / 11 EN

Hood / User Manual

 

 

Page 10
Image 10
Beko CTB 6250 XA, CTB 9250 XA user manual 5Maintenance, Grease Filters