Belkin ST6125D manual ST-4125D/ST-6125D 230/460 VAC Voltage Selection, 230/460VACVoltage Selection

Models: ST6125D ST4125D

1 36
Download 36 pages 48.17 Kb
Page 15
Image 15

ST-4125D/ST-6125D — 230/460 VAC VOLTAGE SELECTION

230/460VACVoltage Selection

The ST-4125D/ST-6125D submersible pump is factory set at 230 VAC. To change the voltage from 230 VAC to 460 VAC, perform the following (refer to Figure 5):

1.Place pump in a suitable area free of dirt and debris.

2.Remove the four retaining screws, using a 19 mm socket, and the two Allen screws using an 8 mm socket, that secure the pump casing.

3.Lift the top of the pump by attaching a chain on the eye bolts and using a crane or similar equipment. Be careful not to fully stretch the cable connections inside the pump.

4.Cut the tie-wrap holding the 460 VAC motor winding wires as shown in Figure 5.Then remove the protective covering from the wires (labeled 4, 5, and 6).

5.Remove the sleeving covering the large red wire and separate the 2 wires labeled 1 and 7.

6.Connect the wire labeled 4 from step 4 to the wire labeled 7 from step 5 and join them with the large red wire. Cover the wires with sleeving.

7.Repeat steps 5 and 6 for the large black wire and the large white wire. Refer to the table in Figure 5 for wires to separate (column 2) and wires to connect (column 4).

8.Using electrical tape, bind the 3 wires that were separated and disconnected (labeled 1, 2, and 3). Place these wires neatly inside the housing.

9.Reinstall the top of the pump and reinsert the six screws and tighten securely.

CUT

TIE-WRAP

WHITE

WHITE

BLACK

(SMALL)

(SMALL)

 

CONNECT

(LARGE)

BLACK

REMOVE PROTECTIVE

COVERING TO GAIN

ACCESS TO 460 VAC

WIRES 4, 5, AND 6.

REMOVE SLEEVING

 

1

2

3

230 VAC

1

 

 

MOTOR

2

 

 

WINDINGS

3

 

 

230 VAC

(LOW VOLTAGE)

W

 

U 9

7

Z

 

X

 

 

Y

 

 

 

 

MOTOR

 

 

 

WINDING

 

 

V

STAR WITH

8

 

NEUTRAL

 

 

 

 

RED

BLACK

TO GROUND

(SMALL)

 

SCREW IN

 

 

 

GREEN

UPPER CASING

 

4

460 VAC

 

5

MOTOR

 

6

WINDINGS

 

5 4

 

6

9

 

8230/460 VAC

MOTOR

 

7

WINDINGS

9

7

COMMON

8

 

460VAC

(HIGH VOLTAGE)

U

X

7

9

 

8

Z

MOTOR

Y

 

 

 

WINDING

 

W

STAR WITH

V

NEUTRAL

 

 

MOTOR WINDING CONFIGURATION

230 VAC

MOTOR

460 VAC

MOTOR

INPUT 3Ø

WINDINGS

INPUT 3Ø

WINDINGS

U (RED)

1 AND 7

U (RED)

4 AND 7

V (WHITE)

2 AND 8

V (WHITE)

5 AND 8

W (BLACK)

3 AND 9

W (BLACK)

6 AND 9

NOTE

PUMP IS SHIPPED FROM THE FACTORY FOR 230 VAC OPERATION.

FOR 460 VAC OPERATION SEE ABOVE WIRING ILLUSTRATION AND TABLE.

 

Figure 5. 230/460 VAC Pump Voltage Selection

ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) — PAGE 15