3.Gently tap the purge nut upside down and sideways to dislodge possible debris taking care not to damage the screen.

4.Blow air in the normal downward direction through the screen to remove debris out the drain hole. Review the warning note.

5.Inspect the o-ring for damage and replace if necessary. Apply a small amount of barium grease to o-ring and place it into the o-ring groove of the purge nut assembly. Reinstall the purge nut into the Cyclone DuraDrainbody. Important: Torque the purge nut to 150 ±10 in-lbs.

6.Reapply air pressure and determine if the leak has been eliminated.

SOLVENT CLEANING

If air leakage was not eliminated by air cleaning, the purge nut may be cleaned in a mineral spirits parts washer. Repeat the removal procedure steps 1 and 2 before proceeding.

7.Wash the hex purge nut in mineral spirits parts washer. Flow solvent downward through the screen and out the drain hole.

8.For stubborn debris, the purge nut may be soaked in the parts washer overnight to dissolve persistent deposits.

9.Apply a small amount of barium grease to o-ring and place it into the o-ring groove of the purge nut assembly. Reinstall the purge nut into the Cyclone DuraDrainbody. Important: Torque the purge nut to 150 ±10 in-lbs.

10.Reapply air pressure and determine if the leak has been eliminated.

11.If the air leak persists, replace the entire purge nut with Bendix service kit piece number 5013824.

Maintenance Kits

Piece No.

Purge Nut Service Kit

5013824

Mounting Spacer Kit

5014792

4

BW2440 © 2010 Bendix Commercial Vehicle Systems LLC. All rights reserved. 5/2010 Printed in U.S.A.