Please check
Filter not well attached

7.Refit the filter case by aligning and inserting it into

the projector slot.

8. Press the case back until it clicks into place.

9. Turn the projector back on.

If the case is not correctly seated in place, the projector will display an on-screen message as pictured to the right every three minutes.

The message will display 3 times for a 10-second duration each, if no further action is taken.

Then a second message as pictured below displays to warn of shutdown in 1 minute.

Please re-attach the filter cap

Otherwise, Power is going to shut down in 1 minute

You can re-attach the case correctly anytime before the projector shuts down. (That means you have 10-11 minutes to get the re-attachment done from the time the first warning message was displayed.) The projector will return to normal operation.

How to replace the filter sponge:

If you find the dirt is hard to remove from the filter sponge or the sponge is broken, replace it.

1.Carefully peel the filter sponge away from the filter case.

See that there are small plastic pins along the edges to position and retain the sponge into place. Lift the sponge up off these pins taking care to prevent them from breaking off.

2.Attach the supplied new filter sponge to the filter case.

Make sure that the tiny holes securely fit onto the case’s pins.

Plastic pins

42 Maintenance

Page 48
Image 48
BenQ MP720 user manual How to replace the filter sponge