14 • 909A & 919A OWNER/OPERATOR MANUAL
DISASSEMBLY FOR CLEANING
1. Turn off and unplug the slicer from the wall outlet.
2. Slide product table toward you.
3. Turn the thickness control knob fully to the right. The gauge plate must be completely closed and
the arm fully forward before the table can be removed.
4. Loosen the product table locking knob.
5. Hold the product table and lift off. Since the pusher can slide or rotate, keep slicing table level.
6. Lift the locking knob on the center plate, hold with both hands and lift off the positioning pin.
WARNING
THE NEXT STEPS WILL EXPOSE THE KNIFE.
7. Remove the sharpener. Loosen the sharpener knob and separate the cover from the sharpener.
8. Push the slice deflector lower hinge tab down with the left hand while holding up on the slice
deflector until the lower deflector pin clears the lower hinge. Pull the deflector out at the bottom
and down to release top pin, then lift deflector free.
9. Clean and sanitize removed parts. Berkel recommends using USDA-approved sanitizer (P/N 4975-
00400). Wash these parts in hot water with detergent or put parts through dishwasher, rinse in hot
water and rinse again in sanitizing solution. Let the parts air dry.
10. Reinstall the sharpener cover/top guard assembly.
11. Clean the slicer base using a cloth and cleaning solution. Rinse with hot water.
CAUTION
TO AVOID MACHINE DAMAGE, DO NOT WASH
MACHINE WITH HIGH PRESSURE WATER OR STEAM.
DO NOT use steel wool or steel wool type soap pads on the knife!
DO NOT allow any food particles to remain on the knife.
DO NOT use any other knife or metal objects to scrape stubborn deposits of sliced
product from knife.
DO NOT leave the knife uncleaned for long periods of time. Clean AT LEAST once
a day.