-CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS:

-CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS:

To change the nozzles of the burners use the following procedure:

Lift up the burners and unscrew the nozzles ( Fig.) using an adjustable spanner of 7 mm and change the nozzles with those designed for the new gas supply according to the information given in TABLE shown below.

Follow the instructions below to change the oven burner nozzle:

1)Remove the oven door (Fig. 9)

2)Remove the lower frontal cavity gasket and the enamelled cavity base plate (Fig. 9)

3)Loosen and the screw V and pull out the burner from the support being careful not to damage the ignition plug and the thermocouple (Fig. 10)

4)Unscrew the nozzle R (Fig. 10) using a 7 mm. spanner and replace it with the nozzle for the new type of gas according to what is indicate in the table below

5)Re-install all the parts in revers sequence from 3 to 1

fig.9

fig.10