Follow the instructions below to change the broiler burner nozzle:
1)Loosen the screw and pull out the burner from the support being careful not to damage the ignition plug and the thermocouple (Fig. 11).
2)Unscrew the nozzle C (Fig. 11) using a 7 mm spanner and replace it with the nozzle needed for the new type of gas according to what is indicated in TABLE shown below.
Fig. 11
Models MTYKQZV4(L,N,D)(2, 5)A
Adapting to different types of gas
Burner | Position | Injector | Gas | Pressure | Max Rate | Min Rate | |||
|
| diam. [mm.] | Type | [i.w.c.] | [BTU/h] | [W] | [BTU/h] | [W] | diam. [mm] |
Auxiliary | Front R | 0,90 | NG | 4” | 3400 | 996 | 900 | 264 | Regulated |
|
| 0,54 | LP (Propane) | 11” | 3400 | 996 | 900 | 264 | 0,29 |
Rear L & C | 1,18 | NG | 4” | 6100 | 1787 | 1500 | 439 | Regulated | |
| Front C | 0,70 | LP (Propane) | 11” | 6100 | 1787 | 1500 | 439 | 0,36 |
Rapid | Rear R | 1,55 | NG | 4” | 10400 | 3047 | 2500 | 732 | Regulated |
|
| 0,92 | LP (Propane) | 11” | 10400 | 3047 | 2500 | 732 | 0,47 |
Dual Burner | Front L Inner | 0,80 | NG | 4” | 2800 | 820 | 900 | 264 | Regulated |
| 0,49 | LP (Propane) | 11” | 2800 | 820 | 900 | 264 | 0,29 | |
| Front L Outer | N°2 x 1,15 | NG | 4” | 12000 | 3516 | 4500 | 1318 | Regulated |
|
| N°2 x 0,70 | LP (Propane) | 11” | 12000 | 3516 | 4500 | 1318 | 0,65 |
Oven | Oven Left | 1,85 | NG | 4” | 14500 | 4248 | 3500 | 1025 | Regulated |
(left cavity) | downside | 1,10 | LP (Propane) | 11” | 14500 | 4248 | 3500 | 1025 | 0,54 |
Broiler | Oven Left | 1,70 | NG | 4” | 12000 | 3516 | Only Max | Only Max | No |
(left cavity) | upside | 0,98 | LP (Propane) | 11” | 12000 | 3516 | Only Max | Only Max | No |
Oven | Oven Right | 1,25 | NG | 4” | 7000 | 2051 | 2400 | 703 | Regulated |
(right cavity) | downside | 0,75 | LP (Propane) | 11” | 7000 | 2051 | 2400 | 703 | 0,48 |
CAUTION: save the orifices removed from the appliance for future use
13